PRODUCT TYPES
Model No. Product name Rated voltage Power failure backup
TB5560187 Analogue type daily TIME SWITCH (with power failure backup) 220-240VAC 300 hours
TB5630187 Analogue type weekly TIME SWITCH (with power failure backup) 220-240VAC 300 hours
TB5590185 Analogue type daily TIME SWITCH 230VAC
__
TB5640185 Analogue type weekly TIME SWITCH 230VAC
__
DIMENSIONS
TB5560187
CIRCUIT DIAGRAM
TB6110187 <1 Circuit type>
SPECIFICATIONS
FEATURES
DIN rail mount
DIN module size
15 minutes interval setting (Daily)
2 hours interval setting (Weekly)
Power supply indication LED lamp
3 state terminal (COM-NO-NC)
Metal setting pin
ON-OFF-AUTO switch
EN50178, DIN57633 conformed
APPLICATIONS
Lighting Fixture
Sign board
Factory facility
Vending machines
HIGH PERFORMANCE
DIGITAL TYPE
TIME SWITCHES
Model No.
Program Cycle
Driving Method
Rated Voltage
Allowable Operating Voltage
Rated Frequency
Power Consumption
Time Indication
Power Supply Indicator
Number of Circuit
Circuit Configuration
Contact Configuration
Manual ON/OFF
Switching Capacity
Resistive Load (cosø=1)
Inductive Load (cosø=0.6)
Setting System
Minimum Setting Unit
Minimum Setting Interval
Number of Operation
Running Reserve
Charging Time
Time Accuracy
Working Ambient Temparature
Working Ambient Humidity
Degree of Protection
Protection Class
Pollution Degree
Over Voltage Category
Wiring Terminal Capacity
Weight
Option Parts
Daily Type Weekly Type Daily Type Weekly Type
Quartz motor AC synchronous motor
220-240V AC 230V AC
-15% to + 10% of rated voltage
50-60Hz 50Hz
2W 2W
Daily dial Weekly dial Daily dial Weekly dial
Green LED Red LED
1-circuit
Separated Circuit (NO voltage-applied contact output)
Single Pole, Double-through ( ):
µ
gap
with ON-AUTO-OFF Switch
250V AC 16A
250V AC 3A
Built-in Pin Setting (inside: ON, Outside: OFF)
15 minutes 2 hours 15 minutes 2 hours
15 minutes 2 hours 15 minutes 2 hours
96/Day 84/Week 96/Day 84/Week
300 hours at 20°C
(Ni-Cd battery built-in) ---
about 72 hours ---
±15 sec/month(at 25°C) Same as AC frequency
-20°C~+55°C
-85%RH or less
IP 20 as per EN60529
Class II as per EN60335-1 if istalled as directed
2
III
1~2.5mm
2
160g 160g
TB55603777 / Terminal Cover
TB5560187 TB5630187 TB5590185 TB5640185
TIME
SWITCHES (TB5)
1
66,5
61
44
33
PIN
INSIDE
NO- ON
NC - OFF
PRESENT
TIME
POWER
1
0
17
16
1
5
15
1
4
1
3
1
2
1
1
1
0
9
8
7
6
5
4
3
2
1
2
3
2
2
2
0
1
9
1
8
1
5
1
2
3
4
5
54
45 90
2
1
2
4
3
2
1
4
5
~
M
POWER COM NO
NC
SAFETY INSTRUCTIONS
1. All operations serving transport, installation, commissioning, troubles-
hooting and maintenance are to be carried out by skilled technical
personnel in accordance with the relevant safety regulations and
standards.
2. Avoid using the time switch except for the environment condition
shown in specifications. Indoor use only.
3. Load capacity differs, depending on the type of load. (See specifications).
4. Protect the circuit with a fuse ir breaker at the power supply, in accor
ONS
dance with the relevant regulations.
5. Synchronous motor type (TB559
.
TB564) are not provided with run-
ning reserve function. When the time error occurs due to power failure,
readjust the present time.
6. Make wiring connections, using isnulated wire (1,0 to 2,5 mm
2
).
Flexible codes conductors 1,0 to 2,5mm
2
.
Fixed wiring conductors 1,5 to 2,5mm
2
.