Heath Zenith SL-5210 Owner's Manual

Download Owner's manual of Heath Zenith SL-5210 Security System, Work Light for Free or View it Online on All-Guides.com.

Heath Zenith SL-5210 Owner's manual - Page 1
1
Heath Zenith SL-5210 Owner's manual - Page 2
2
Heath Zenith SL-5210 Owner's manual - Page 3
3
Heath Zenith SL-5210 Owner's manual - Page 4
4
Heath Zenith SL-5210 Owner's manual - Page 5
5
Heath Zenith SL-5210 Owner's manual - Page 6
6
Heath Zenith SL-5210 Owner's manual - Page 7
7
Heath Zenith SL-5210 Owner's manual - Page 8
8
Heath Zenith SL-5210 Owner's manual - Page 9
9
Heath Zenith SL-5210 Owner's manual - Page 10
10
Heath Zenith SL-5210 Owner's manual - Page 11
11
Heath Zenith SL-5210 Owner's manual - Page 12
12
Features
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight hours.
Requirements
• The light control requires 120-volts AC.
• If you want to use Manual Override, the control must be
wired through a wall switch.
Some codes require installation by a qualified
electrician.
• Switch Module mounts into a standard 4" x 4" junction box.
The SL-5210 package includes:
• The Sensor Module and Switch Module
• Three wire nuts
• Two sensor module screws
© 2007 HeathCo LLC 595-4991-07
Motion Sensor
Decorative Lighting
Control
Model SL-5210
Switch Mod-
ule In Junction
Box Behind
Light Fixture
Sensor Module
Sensor Cord
Existing Light Fixture
Typical Installation
Drip Loop
NOTE: The Drip Loop is neccessary to prevent rain from
running down the cord to the Sensor Module.
OPERATION
Move ON-TIME Switch to 1,
5, or 10 minutes
Mode Switching Summary
Flip switch off for one
second then back on*
* resets to Auto Mode at dawn.
TEST
AUTO
MANUAL MODE
ON-TIME
ON-TIME
* If you get confused while switching modes, turn the power
off for one minute, then back on. After the calibration time
(1
1
/
2
min.) the control will be in the AUTO mode.
10 5 1 TEST
10 5 1 TEST
MANUAL MODE
AUTO
TEST
... back on.
1 Second OFF
then...
Manual mode only works at night because
daylight returns the sensor to AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO and
MANUAL MODE.
Manual mode works only with the ON-TIME
switch in the 1, 5, or 10 position.
Note: When first turned on wait about 1
1
/
2
minutes for the
circuitry to calibrate.
Put the ON-TIME switch in the 1, 5, or 10
minute position.
Put the ON-TIME switch on the bottom of the
sensor in the TEST position.
Mode: On-Time: Works: Day Night
Test
5 Sec
x x
Normal
1, 5, 10 min.
x
Manual
Until Dawn*
x