Hewlett-Packard 166207-B21 - Smart Array 5302/32 RAID Controller Reference Manual

Download Reference manual of HP 166207-B21 - Smart Array 5302/32 RAID Controller Adapter, Controller for Free or View it Online on All-Guides.com. This version of HP 166207-B21 - Smart Array 5302/32 RAID Controller Manual compatible with such list of devices, as: 225338-B21 - Smart Array 532 RAID Controller, 411508-B21 - Smart Array E200/128 BBWC Controller RAID, ProLiant DL320e, ProLiant DL380e, ProLiant ML350e

HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 1
1
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 2
2
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 3
3
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 4
4
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 5
5
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 6
6
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 7
7
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 8
8
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 9
9
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 10
10
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 11
11
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 12
12
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 13
13
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 14
14
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 15
15
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 16
16
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 17
17
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 18
18
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 19
19
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 20
20
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 21
21
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 22
22
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 23
23
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 24
24
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 25
25
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 26
26
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 27
27
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 28
28
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 29
29
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 30
30
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 31
31
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 32
32
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 33
33
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 34
34
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 35
35
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 36
36
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 37
37
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 38
38
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 39
39
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 40
40
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 41
41
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 42
42
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 43
43
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 44
44
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 45
45
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 46
46
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 47
47
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 48
48
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 49
49
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 50
50
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 51
51
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 52
52
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 53
53
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 54
54
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 55
55
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 56
56
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 57
57
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 58
58
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 59
59
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 60
60
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 61
61
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 62
62
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 63
63
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 64
64
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 65
65
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 66
66
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 67
67
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 68
68
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 69
69
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 70
70
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 71
71
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 72
72
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 73
73
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 74
74
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 75
75
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 76
76
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 77
77
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 78
78
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 79
79
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 80
80
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 81
81
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 82
82
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 83
83
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 84
84
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 85
85
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 86
86
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 87
87
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 88
88
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 89
89
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 90
90
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 91
91
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 92
92
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 93
93
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 94
94
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 95
95
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 96
96
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 97
97
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 98
98
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 99
99
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 100
100
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 101
101
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 102
102
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 103
103
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 104
104
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 105
105
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 106
106
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 107
107
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 108
108
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 109
109
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 110
110
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 111
111
HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference manual - Page 112
112
HP Array Configuration Utility 61
=> ctrl ch="Lab 4" delete forced
=> ctrl slot=3 ld all delete
Generating a diagnostic report
Previously a function of the ADU CLI, diagnostic capability is now part of the ACU CLI.
The diag command outputs diagnostic information about a specified controller or all controllers on the
system.
Syntax:
<target> diag <file=filename> [ris=on|off] [xml=on|off] [zip=on|off]
where the following is designated:
<target> is a controller or all controllers
<file=filename> designates the target file in which the diagnostic information is saved
[ris=on|off] determines whether RIS information is or is not included
[xml=on|off] outputs diagnostic information in formatted XML
[zip=on|off] compresses the output to a zipped file. Default behavior is uncompressed.
Example commands:
=> ctrl all diag file=c:\allcontrollers.txt xml=on
=> ctrl slot=4 diag file=c:\ctrl_slot4.txt ris=off zip=on
=> ctrl ch="mybox" diag file=mybox.txt ris=on xml=off zip=on
Erasing a physical or logical drive
Syntax:
<target> modify [erase
erasepattern=zero|random_zero|random_random_zero][deleteaftererase=yes|n
o]
where the target can be any valid physical drive or logical drive. The option to delete the target after
erasing it is valid only if the target is a logical drive.
To stop an erase process at any time, enter the stoperase command.
Example commands:
=> ctrl slot=3 ld 2 modify erase erasepattern=zero
=> ctrl slot=4 ld=all modify erase erasepattern=random_zero
=> ctrl slot=3 ld 2 modify stoperase
Rescanning the system
A rescan detects devices that have been added to the system since the previous rescan or since the ACU
CLI was started, whichever is more recent.
Syntax:
Use the word rescan directly at the ACU CLI prompt, without any target device or parameters.
Example command:
=> rescan