Hewlett-Packard 2000fc Reference Manual
Download Cli reference manual of HP 2000fc Adapter, Switch for Free or View it Online on All-Guides.com.
208 HP StorageWorks 2000 Family Modular Smart Array CLI reference guide • May 2008
show redundancy-mode
Description
Shows the redundancy status of the system.
Input
Output
show redundancy-mode
Field Description
Redundancy Mode The redundancy mode, also called the “operation mode.”
• Active-Active ULP: SAS only. Both controllers
are active using ULP (Unified LUN Provisioning),
which means 128 LUNs are available for mapping
volumes.
• Active-Active: FC and iSCSI only. Both controllers
are active, and each has 128 LUNs for mapping
volumes owned by that controller only.
• Independent Cache Performance Mode:
Cache mirroring and failover between controllers is
disabled, which results in improved write performance
but at a risk of loss of unwritten data if a controller
failure occurs while there is data in the controller’s
cache memory.
• Single-Controller: There is only one controller in
the enclosure.
Redundancy Status • Redundant: Both controllers are operational.
• Operational but not redundant:
In active-active mode, one controller is operational and
the other is offline. In single-controller mode, the
controller is operational.
• Redundant with independent cache: Both
controllers are operational with cache mirroring
disabled.
Controller ID
Status
• Operational: The controller is operational.
• Down: The controller is installed but not operational.