Hewlett-Packard 418800-B21 - StorageWorks Modular Smart Array 70 Storage Enclosure Firmware Release Notes

Download Firmware release notes of HP 418800-B21 - StorageWorks Modular Smart Array 70 Storage Enclosure Adapter, Carrying Case for Free or View it Online on All-Guides.com.

HP 418800-B21 - StorageWorks Modular Smart Array 70 Storage Enclosure Firmware release notes - Page 1
1
HP 418800-B21 - StorageWorks Modular Smart Array 70 Storage Enclosure Firmware release notes - Page 2
2
HP 418800-B21 - StorageWorks Modular Smart Array 70 Storage Enclosure Firmware release notes - Page 3
3
HP 418800-B21 - StorageWorks Modular Smart Array 70 Storage Enclosure Firmware release notes - Page 4
4
HP 418800-B21 - StorageWorks Modular Smart Array 70 Storage Enclosure Firmware release notes - Page 5
5
HP 418800-B21 - StorageWorks Modular Smart Array 70 Storage Enclosure Firmware release notes - Page 6
6
HP 418800-B21 - StorageWorks Modular Smart Array 70 Storage Enclosure Firmware release notes - Page 7
7
HP 418800-B21 - StorageWorks Modular Smart Array 70 Storage Enclosure Firmware release notes - Page 8
8
HP 418800-B21 - StorageWorks Modular Smart Array 70 Storage Enclosure Firmware release notes - Page 9
9
HP 418800-B21 - StorageWorks Modular Smart Array 70 Storage Enclosure Firmware release notes - Page 10
10
Smart Component installation instructions for Linux environments
1. Place the Smart Component in a temporary directory.
2. Open a Linux command console.
3. From the directory containing the downloaded file, enable execute access to this model by typing
chmod +x CPxxxxxx.scexe, where CPxxxxxx.scexe represents the downloaded file.
4. Execute the Smart Component by entering a command similar to the following: ./
CPxxxxxx.scexe --target <ip_address> --user <manage_username> --passwd
<password>
If the user name or password contains an exclamation mark (!), enclose the string in single quotes
or enter a backslash (\) before the exclamation point. For example, '!manage' or \!manage.
5. Follow onscreen instructions.
NOTE:
When prompted for logon information, enter credentials for an account with management
access rights.
Binary file installation instructions using Storage Management Utility (SMU)
WARNING!
Do not perform a power cycle or controller restart during a firmware update. If the update is interrupted
or there is a power failure, the module might become inoperative. If this occurs, contact technical
support. The module might need to be returned to the factory for reprogramming.
1. Obtain the appropriate firmware file and download it to your computer or network.
2. If the system has a single controller, stop I/O to vdisks before starting the firmware update.
3. In the Configuration View panel, right-click the system and select Tools > Update Firmware. The
tables titled Current Versions of Controller Module A and Current Versions of Controller Module
B show the currently installed versions.
4. Click Browse and select the firmware file to install.
5. Click Install Controller-Module Firmware File. It takes approximately 10 minutes for the firmware
to load and for the automatic restart to complete on the controller you are connected to. Wait
for the progress messages to specify that the update has completed. If Partner Firmware Update
is enabled, allow an additional 20 minutes for the partner controller to be updated.
6. Verify that the proper firmware version appears for each controller module.
8