background image

Hewlett-Packard Storage Processor (SP)

 Installation Guide

Hewlett-Packard SPs are customer installable and replaceable. A replacement SP must be the same type as the SP being 
replaced.

The locations of the SPs in the 30-slot disk arrays are shown in Figure 1.

.

Figure 1.

Install an SP by performing the following steps.  Place a check in the appropriate 

o

 as the step is completed.

Step 1:

Observe antistatic precautions

An SP is shipped with an ESD kit containing:

ESD  wrist  strap

ESD conductive sheet

o

Ground the ESD wrist strap to the metal edge above the 
rear retaining screws and fasten the strap to your wrist. 

Step 2: 

Prepare to install the SP

o

Remove the replacement SP from its shipping carton 
and place it on a suitable antistatic work surface or the 
ESD conductive sheet.

Array power can be left on during SP removal and 
replacement. 

o

Remove the failed SP.

o

Remove the memory modules from the failed SP.

o

Insert memory modules in the SIMM connectors on the 
SP to be installed. 

See the 

2EMOVAL AND 2EPLACEMENT chapter in the 

(EWLETT 0ACKARD (IGH !VAILABILITY &IBRE #HANNEL

$ISK !RRAY 5SER 'UIDE for more information about 
SIMM removal and replacement.

SP-A

SP-B

Rear view, top of the disk array