,VRODWLQJ)DXOWV 99
Troubleshooting
Isolating Faults
7DEOH OLVWVWKHSUREDEOHFDXVHVDQGVROXWLRQVIRUSUREOHPV\RXPD\GHWHFWRQWKHGLVN
V\VWHP:KHQPRUHWKDQRQHSUREOHPDSSOLHVWR\RXUVLWXDWLRQLQYHVWLJDWHWKHILUVW
GHVFULSWLRQWKDWDSSOLHV7KHWDEOHOLVWVWKHPRVWEDVLFSUREOHPVILUVWDQGH[FOXGHVWKHP
IURPVXEVHTXHQWSUREOHPGHVFULSWLRQV
7DEOH 7URXEOHVKRRWLQJ7DEOH
Problem
Description
HW Event
Category
LED
State
STM
Status Probable Cause/Solution
Installed
product does
not power on
none System
power LED
off
none – Neither power cord is plugged in.
– The power switch is not pressed.
– AC breaker is tripped.
– AC power source has failed.
– The PDU/PDRU is defective.
– Power switch is defective.
– A faulty component is causing power
supplies to turn off. Remove all
components and reinsert one at a time
until the faulty component is isolated.
System fault
LED is on
none Power
supply
LED off
Power
supply Not
Available
– The power supply is not plugged in.
– The PDU/PDRU or primary power source
has failed.
Critical Part fault
LED on
Critical A component has failed. See problem
descriptions below.
Audio alarm
when BCC
installed
none BCC Fault
flashing
Disk Not
Available
BCC DIP switch settings do not match peer
BCC switch settings. Reset switches.
BCC Fault
LED is on
Critical BCC Fault
on
Critical BCC hardware is faulty. Replace the BCC.
Fan LED is
amber
Critical Amber Critical Fan has slowed or stopped. Replace the
fan.