Installation Procedures - All Deployments
59HP StorageWorks 1500 Modular Smart Array Installation Guide
Read the messages on the controller display panel
Each controller contains an integrated LCD panel. This panel displays
informational and error messages, shows the current status of the MSA, and
provides an interface for user input. To verify that your MSA is operating
properly, use the arrow buttons on the LCD panel of the controller and look for the
following messages:
If the
Startup Complete message is not displayed:
■ Check the cable connections to the MSA
■ Check the availability of your power source
■ Review the setup instructions in the previous sections of this guide
■ Refer to the HP StorageWorks MSA1500 Maintenance and Service Guide,
available on the Documentation CD and the Technical documents page of the
MSA1500 website:
http://www.hp.com/go/m sa1500cs
.
Go to Table 10: “MSA1500 Information” on page 108 to record the controller
firmware version.
Table 8: MSA1500 Startup Messages
Message Meaning
Startup Complete The array controller has completed its
power on sequence and is operational.
Fibre Sub-System Link Failure No active fiber connection to the MSA
controller exists. This message is
expected, because, although you have
physically installed the HBA in the
server, you have not yet installed the
drivers for the HBA and the MSA.
You may safely ignore this message.
Array controller Firmware ver
<version>
The current version of the firmware
running on the controller.