Configuration Procedures - HP-UX Environments
84 HP StorageWorks 1500 Modular Smart Array Installation Guide
Installing the ACU-CLI on the servers (optional)
To use the ACU-CLI to configure MSA storage, perform the following steps to
install it on the servers:
Note:
■ You must remove earlier versions of the ACU before installing later versions.
■ For information about using the ACU-CLI, see ACU-CLI online help, the HP-UX
ACU-CLI readme file or release notes, or the HP Configuring Arrays Reference
Guide.
1. Insert the Support Software CD in the CD-ROM drive of the server.
Note: If you created a new Support Software CD from the Web, insert that CD in the
CD-ROM drive of the server and do not use the shipping version of the CD. For more
information, see:
■ “Determine which version MSA controller firmware to use” on page 17
■ “Obtain desired controller firmware and Support Software CD versions” on page 61
2. From the console, mount the CD-ROM drive and navigate to the
/HPUXACUCLI/HP-UX directory for your environment.
3. List the contents of the directory and identify the ACU-CLI depot file for your
environment.
4. Copy the ACU-CLI depot file and its corresponding readme file to a
temporary directory on the server. For example:
# cp /HPACUCLI/HP-UX/IA64/HPACUCLI_IA_v7.47-1.depot .tmp
5. Install the ACU-CLI application using the swinstall command. For example:
# swinstall -s /tmp/HPACUCLI_IA_v7.47-1.depot
6. Remove the Support Software CD from the CD-ROM drive.
Note: To start the ACU-CLI, do the following from the console: Navigate to the
/opt/compaq/hpacucli/bld directory, and then enter # ./hpacucli
.