Message Type
Description Action
151 BEACON OFF
Informational
The LEDs on the MSA and
all connected hard drives
are no longer blinking
because the host-based
application is no longer
identifying or configuring
this MSA.
201 ARRAY
CONTROLLER
TEMPERATUR
EOK
Informational
The temperat
ure sensor
on the array
controller
indicates t
hat the
temperatur
ethatwas
previousl
yexceedingthe
normal ope
rating range is
now back wi
thin the range.
202 ARRAY
CONTROLLER
OVERHEATING
Error
The temperature sensor
on the array controller
indicates that the array
controller is starting
to exceed the normal
operating range.
Check all MSA fans and
ensure they are operating.
Any failed fan should be
replaced. Ensure that there
is a module or blanking
panel (cover plate) in all
MSA chassis bays and slots.
Empty bays affect the airflow
and cooling ability of the
MSA.
203 ARRAY
CONTROLLER
OVERHEATED
Error
The temperature sensor
on the array controller
indicates that the array
controller has exceeded the
safe operating range.
The MSA should be powered
off as soon as possible to
avoid hardware failure.
Check all MSA fans and
ensure they are operating.
Any failed fan should be
replaced. Ensure that there
is a module or blanking
panel (cover plate) in all
MSA chassis bays and slots.
Empty bays affect the airflow
and cooling ability of the
MSA.
20
4 ARRAY
C
ONTROLLER DISABLED
Er
ror
T
he array controller has
b
een disabled due to a
r
edundancy failure.
Remove the failed array
controller, wait 10 seconds,
and then reinsert the array
controller, ensuring that it is
fully seated in the chassis.
Should the issue persist,
contact HP support.
205 ARRAY
CONTROLLER
RESTARTING
Informational
The array controller has
completed firmware cloning
and will be restarted
automatically.
300 RECOVERY ROM
AUTOFLASH STARTED
Informational
The array controller has
detected that the firmware's
backup recovery ROM
image is invalid and is
copying the current active
firmware image into the
backup recovery ROM.
maintenance and service guide
53