Hewlett-Packard GbE2c - Blc Layer 2/3 Fiber SFP Option Application Manual
Download Application manual of HP Xw460c - ProLiant - Blade Workstation Desktop, Enclosure for Free or View it Online on All-Guides.com.
Brand: HP
Category: Desktop , Enclosure , Other , Printer , Server , Software , Switch
Type: Application manual
Model: HP Xw460c - ProLiant - Blade Workstation , HP GbE2c - Blc Layer 2/3 Fiber SFP Option
Pages: 165 (7.93 Mb)
Download HP Xw460c - ProLiant - Blade Workstation Application manual
Remote monitoring 137
Configure RMON Alarms (BBI example 2)
1. Configure an RMON Alarm group.
a. Click the Configure context button.
b. Open the Switch folder, and select RMON > Alarm > Add Alarm Group.
c. Configure RMON Alarm Group parameters to check icmpInEchos, with a polling interval of 60, a rising
limit of 200, and a rising event index of 5. This configuration creates an RMON alarm that checks
icmpInEchos on the switch once every minute. If the statistic exceeds 200 within a 60 second interval, an
alarm is generated that triggers event index 5.
2. Click Submit.