SIP User's Manual 288 Document #: LTRT-68809
Mediant 2000
Parameter Description
Web/EMS: Registration Retry Time Defines the time interval (in seconds) after which a
Registration request is resent if registration fails with a 4xx
response or if there is no response from the Proxy/Registrar
server.
The default is 30 seconds. The range is 10 to 3600.
[RegistrationRetryTime]
Web: Registration Time Threshold
EMS: Time Threshold
Defines a threshold (in seconds) for re-registration timing. If
this parameter is greater than 0, but lower than the computed
re-registration timing (according to the parameter
RegistrationTimeDivider), the re-registration timing is set to the
following: timing set by the Registration server in the Expires
header minus the value of the parameter
RegistrationTimeThreshold.
The valid range is 0 to 2,000,000. The default value is 0.
[RegistrationTimeThreshold]
Web: Re-register On INVITE Failure
EMS: Register On Invite Failure
Enables immediate re-registration if a failure response is
received for an INVITE request sent by the device.
[RegisterOnInviteFailure]
[0]
Disable = Disabled (default)
[1]
Web: ReRegister On Connection
Failure
EMS: Re Register On Connection
Failure
Enable = Enabled
Enables the device to perform SIP Re-Registration upon
TCP/TLS connection failure.
[ReRegisterOnConnectionFailure]
[0]
Disable (default).
[1]
Web: Gateway Registration Name
EMS: Name
Enable.
Defines the user name that is used in the From and To
headers in REGISTER messages. If no value is specified
(default) for this parameter, the UserName parameter is used
instead.
[GWRegistrationName]
Note:
Web/EMS: Authentication Mode
This parameter is applicable only for single registration
per device (i.e., AuthenticationMode is set to 1). When the
device registers each channel separately (i.e.,
AuthenticationMode is set to 0), the user name is set to the
channel's phone number.
Determines the device's registration and authentication
method.
[AuthenticationMode]
[0] Per Endpoint = Registration and Authentication
separately for each B-channel
.
[1]
Single Registration and Authentication (Authentication Mode =
1) is usually defined for
Per Gateway = Single Registration and Authentication
for the entire device (default).
and digital modules
.