Hewlett-Packard 1280 - Ultra VGA - 17" CRT Display User's Manual

Download Operation & user’s manual of HP 1280 Monitor, Printer for Free or View it Online on All-Guides.com.

Brand: HP

Category: Monitor , Printer

Type: Operation & user’s manual for HP 1280

Pages: 19 (1.33 Mb)

Download HP 1280 Operation & user’s manual

HP 1280 Operation & user’s manual - Page 1
1
HP 1280 Operation & user’s manual - Page 2
2
HP 1280 Operation & user’s manual - Page 3
3
HP 1280 Operation & user’s manual - Page 4
4
HP 1280 Operation & user’s manual - Page 5
5
HP 1280 Operation & user’s manual - Page 6
6
HP 1280 Operation & user’s manual - Page 7
7
HP 1280 Operation & user’s manual - Page 8
8
HP 1280 Operation & user’s manual - Page 9
9
HP 1280 Operation & user’s manual - Page 10
10
HP 1280 Operation & user’s manual - Page 11
11
HP 1280 Operation & user’s manual - Page 12
12
HP 1280 Operation & user’s manual - Page 13
13
HP 1280 Operation & user’s manual - Page 14
14
HP 1280 Operation & user’s manual - Page 15
15
HP 1280 Operation & user’s manual - Page 16
16
HP 1280 Operation & user’s manual - Page 17
17
HP 1280 Operation & user’s manual - Page 18
18
HP 1280 Operation & user’s manual - Page 19
19
HP Ultra VGA 1280 User’s Guide
Technical Specifications
10 English
Technical Specifications
1. Use the standard image sizes to avoid distortion of the displayed image.
PICTURE TUBE
Size 17-inch flat screen/ 15.7-inch viewable image
Phosphorous Red, Green, Blue short persistence
Dot pitch 0.28 mm
Face Plate Anti-glare, multilayer coating
INPUT SIGNAL
Video 0.660 Vp p analog RGB
Synchronization Separated H/V (TTL level), H/V mixed (TTL level)
INTERFACE
Input Connector 15-pin mini D-SUB
SCANNING FREQUENCY
Horizontal 30 to 69 kHz
Vertical 50 to 160 Hz
MAX. RESOLUTION (H
×
V)
1280
×
1024 (60 Hz)
WARM-UP TIME
30 minutes to reach optimum performance level
PIXEL CLOCK
110 MHz
IMAGE SIZE
Standard size
1
:306(H) x 230(V) mm
Maximum size: 320(H) x 240(V) mm
POWER SOURCE
AC 90 to 264 V, 47 to 63 Hz, 100W (max), less than 15 W in Standby mode, less than 5 W in Sleep mode,
less than 1 W when switched off.
OPERATING ENVIRONMENT
Temperature 5
°
C to 40
°
C (operating)
- 40
°
C to +65
°
C (storage)
Humidity 5% RH through 90% RH (without condensation)
CABINET DIMENSIONS
425(H)
×
424(W)
×
444(D) mm (with stand)
WEIGHT
19 kg
TILT/SWIVEL STAND
Tilt Angle - 5
°
to +13
°
Swivel Angle
±
45
°