A5277AZ Factory Configuration for 1 Disk Enclosure
Recommended FC60 Configuration
Single host, dual-controller disk array, 1 disk enclosure, 5 RAID 1 LUNs
FCAL-B
LVD
SCSI
LVD
SCSI
FCAL-A
Red and Blue drives are on separate SCSI buses
LUN 0
LUN 1 LUN 2
LUN 3
LUN 4
FC60 Enclosure
Controller A Controller B
SC10 Disk Enclosure
BCC A
BCC B
Hardware Configuration
FC60 controllers connected directly to host FC adapters
One disk enclosures with ten 18 GB disk modules in each
Disk enclosure set to split-bus mode by setting option
switch 1 DOWN on BCCs
Unused SCSI connectors on FC60 enclosure must be terminated
Expansion SCSI connector on disk enclosure must be terminated
LUN Configuration
Five RAID 1 LUNs, comprising 2 disks each (1+1)
Each disk in the LUN is in a separate enclosure
High Availability
Handles the failure of a single disk, controller, BCC, or SCSI channel
Does not handle the failure of the disk enclosure
Disk Capacity
Maximum capacity ~180 GB
Usable capacity ~90 GB
Host