Hewlett-Packard Integrity cx2600 Maintenance Manual
Download Maintenance manual of HP Integrity cx2600 Server for Free or View it Online on All-Guides.com.
Table 4-4 Rear Panel LED Definitions (continued)
DescriptionColorLED/Button
Lit when a power supply failure is detected. Indicates that power
supply has been cycled down or is not fully functional.
AmberPower Supply Fault
Lit when a power supply is operating normally. Indicates that DC
power is being supplied to server circuits.
GreenPower Supply DC Out
Lit when power (-36 to -72 VDC) is supplied to the power supply.
Indicates that source power is available.
GreenPower Supply DC In
Error Messages
Server firmware and management features monitor system operation, report errors, and log all
significant events.
This section presents error message and log information.
EFI Error and Warning Messages
EFI error and warning messages are displayed on the console as part of the boot process. They
can also be retrieved using the EFI info warnings command. Table 4-5 lists possible error
messages.
Table 4-5 EFI Error and Warning Messages
Description/SolutionMessageError Number
Incorrect I/O configuration. Contact the HP
Support Center for assistance.
Insufficient resources to assign to one or more
I/O devices
2
Incorrect I/O configuration. Contact the HP
Support Center for assistance.
Unexpected hardware I/O configuration4
Update BMC firmware.No BMC installed on the platform7
Check system logs for errors. Replace the system
board.
BMC cannot be accessed8
Communication with the BMC failed. Check
power. Replace the system board.
One or more BMC ports failed9
Clear the SEL.BMC system event log is full10
Contact the HP Support Center for assistance.Platform silicon-controlled rectifier (SCR) is bad11
Communication with the BMC failed. Replace the
system board.
Set time to BMC SEL failed12
Communication with the BMC failed. Replace the
system board.
SEL get info failed
13
Communication with the BMC failed. Replace the
system board.
Initial BMC SEL event failed14
Communication with the BMC failed. Replace the
system board.
Update of BMC buffered data failed15
Communication with the BMC failed. Replace the
system board.
All advanced configuration and power interface
(ACPI) BMC ports bad
16
Communication with the BMC failed. Replace the
system board.
Read error on BMC token17
Communication with the BMC failed. Replace the
system board.
BMC token transmit checksum error
18
62 Troubleshooting