Table 4-5 EFI Error and Warning Messages (continued)
Description/SolutionMessageError Number
Communication with the BMC failed. Replace the
system board.
Error writing BMC token on download19
Communication with the BMC failed. Replace the
system board.
Non-volatile Memory (NVM) token access error20
Communication with the BMC failed. Replace the
system board.
BMC token write error during NVM write
through
21
Communication with the BMC failed. Replace the
system board.
Error reading BMC token on upload to NVM22
Communication with the BMC failed. Replace the
system board.
Error reading BMC first boot token23
Reflash firmware.Primary field interoperability testing (FIT) failed24
Reflash firmware.Secondary FIT failed25
Reflash firmware.Processor abstraction layer (PAL) A warning;
One copy of PAL is bad
26
Update firmware.PAL A warning; PAL is not compatible with at
least 1 CPU
27
Reseat DIMMs; if error persists replace bad
DIMMs.
Memory errors detected and Page Deallocation
Table (PDT) is disabled
28
Information only, no action required.Memory required reinterleave to get a good
page 0
30
Information only, no action required.One or more ranks have chipspare disabled31
Check memory installation. Match DIMM part
numbers within each quad.
One or more memory ranks are mismatched or
deallocated
33
Check memory installation. DIMMs must be
installed with smallest capacity in the first quad,
Memory deallocated because of a loading error34
an equal or larger capacity in the second quad, and
an equal or larger capacity in the third quad.
Check memory installation. DIMMs must be
installed with smallest capacity in the first quad,
Memory load order error35
an equal or larger capacity in the second quad, and
an equal or largest capacity in the third quad.
Clear with pdt clear command in the EFI Shell.
The PDT is full36
Check processor installation. Verify installation
and that identical processors have been installed.
At least one CPU has bad fixed core ratio37
Processor failure. Verify installation and replace
processor. Contact the HP Support Center for
assistance.
All CPUs were slated for compatibility
deconfiguration
38
Check processor installation and match CPU part
numbers. CPUs must be identical.
Incompatible CPUs detected39
Check processor installation. Match CPU part
numbers. CPUs must be identical. This always
causes a stopboot.
CPUs installed with mixed cache sizes40
Check processor installation and match CPU part
numbers. CPUs must be identical.
CPUs installed with mixed steppings41
Check processor installation and match CPU part
numbers. CPUs must be identical.
All CPUs are overclocked42
Error Messages 63