Honeywell HW-QUICK12E Instruction Manual

Download Instruction manual of Honeywell HW-QUICK12E Air Conditioner for Free or View it Online on All-Guides.com.

Brand: Honeywell

Category: Air Conditioner

Type: Instruction manual for Honeywell HW-QUICK12E

Pages: 20 (1.17 Mb)

Download Honeywell HW-QUICK12E Instruction manual

Honeywell HW-QUICK12E Instruction manual - Page 1
1
Honeywell HW-QUICK12E Instruction manual - Page 2
2
Honeywell HW-QUICK12E Instruction manual - Page 3
3
Honeywell HW-QUICK12E Instruction manual - Page 4
4
Honeywell HW-QUICK12E Instruction manual - Page 5
5
Honeywell HW-QUICK12E Instruction manual - Page 6
6
Honeywell HW-QUICK12E Instruction manual - Page 7
7
Honeywell HW-QUICK12E Instruction manual - Page 8
8
Honeywell HW-QUICK12E Instruction manual - Page 9
9
Honeywell HW-QUICK12E Instruction manual - Page 10
10
Honeywell HW-QUICK12E Instruction manual - Page 11
11
Honeywell HW-QUICK12E Instruction manual - Page 12
12
Honeywell HW-QUICK12E Instruction manual - Page 13
13
Honeywell HW-QUICK12E Instruction manual - Page 14
14
Honeywell HW-QUICK12E Instruction manual - Page 15
15
Honeywell HW-QUICK12E Instruction manual - Page 16
16
Honeywell HW-QUICK12E Instruction manual - Page 17
17
Honeywell HW-QUICK12E Instruction manual - Page 18
18
Honeywell HW-QUICK12E Instruction manual - Page 19
19
Honeywell HW-QUICK12E Instruction manual - Page 20
20
15
ENGLISH
Installing the drainage of condensation of the outdoor unit
The outdoor unit may produce condensation. This condensation needs to be led
away by a drainage hose. Install the drainage hose as follows:
Insert the outdoor drain elbow into the hole of 25 mm at the bottom of the outdoor
unit as shown in the figure. Thereafter connect the plastic drain hose with the
assembled outdoor drain elbow. Now the condensation can be led away correctly.
Trial run
1. Preparation for trial run
1. Do not connect power cord and do not switch on the air conditioner until the
entire installation is completed.
2. Tidy up all scattered components, especially metal parts and any installation
material etc. before starting the trial run.
3. Make sure the unit is fully assembled according to these instructions.
2. Trial running method
After pressing a key the unit will start operation with a delay of 3-4 minutes to
avoid a damage of the compressor.
The unit stops and then restarts.
The unit operates according to pre-adjusted keys.
If all above mentioned points are checked, plug in the power cord of the indoor unit and switch
it on by setting the COOL Mode. Check if the air conditioner delivers cool air. Furthermore
check if there is an abnormal noise, vibration or water leakage at the indoor unit and outdoor
unit as well as at the quick connector.
If everything is ok with the complete unit and you do not have to disassemble the unit to
correct mistakes produced during installation, use the delivered gum type sealer to close vents
around the connection piping and wiring within the hole of the wall.
Bottom of Outdoor Unit
Outdoor Drain Elbow
Check After Installation
Items to be checked Possible malfunction if not installed correctly
Is the installation firm enough? The unit may drip, shake or produce noise
Is heat insulation sufficient? Condensation or water drop may occur
Is the drainage smooth? Condensation or water drop may occur
Does the power voltage correspond to the data of the rating label?
Malfunction of the air conditioner or burnout of electric parts of the air conditioner
may occur
Is the installation of circuit and pipe correct?
Malfunction of the air conditioner or burnout of electric parts of the air conditioner
may occur
Is the unit earthed safely? Creepage may occur
Does the model of wire correspond to the regulation?
Malfunction of the air conditioner or burnout of electric parts of the air conditioner
may occur
Are the air inlet and outlet vents of the indoor and outdoor unit blocked? It may lead to insufficient capacity of cooling or heating
HW-QUICK12E_GB_OM.qxd 4/2/07 12:04 PM Page 15