5800PIR-OD Wireless Outdoor Motion Sensor – Installation Instructions
GENERAL INFORMATION
The Honeywell 5800PIR-OD Wireless Outdoor Motion Sensor
(referred to as the 5800PIR-OD) combines the convenience of
wireless technology with a full featured outdoor PIR motion
sensor. The major features are highlighted below:
Immunity to bright light
disturbances from headlights,
sunlight, and other bright
light sources.
Selectable detector
range and angle.
Discriminates both large and
small animals to reduce false
alarms.
Tamper detection.
Battery saving circuit
allows for a 5 or 120
second period of
inactivity before being
reactivated.
SPECIFICATIONS
Detection Method
Passive Infrared
Initial Warm Up
~ 2 minutes
Dimensions
Height 199mm (7.8 in.)
Width 82mm (3.2 in.)
Depth 120mm (4.7 in.)
Mounting Height
0.8 - 1.2m (2.7 - 4ft) To the center of
lens.
Range
Adjustable up to 12m (40ft)
Pattern
90° pattern consisting of 13 zones. This
pattern can be adjusted in 15° incre-
ments from center up to 45°.
Sensitivity
2.0° C at 0.6m/s (3.6° F at 2.0ft/s)
Detection Speed
0.3 - 1.5m/s (1 - 5ft/s)
Operating Voltage
6 VDC (uses 4 lithium 1.5VDC AA cells)
Battery Saving Timer
Adjustable 120sec or 5sec
Alarm Period
~ 2.5 seconds
LED Indicator
Enabled during a walk test.
Disabled for normal operation.
Weatherproof
IP54 compliance
Operating Temperature
– 20 to + 50 ° C (– 4 to +122° F)
Humidity
95% Max
Accessories (included)
Pole mounting kit, screw kit, detection
masking strips.
INSTALLATION (refer to the Component Identification Diagram on page 7)
1 Select the Mounting Position
Avoid strong sunlight into the sensor's field.
Avoid moving or swaying trees and bushes.
Orient the detector
so that intrusion
passes across the
detection field, not
into the sensor.
Allow 110mm (4.4")
above the sensor to
enable opening the cover.
Choose an installation
height of 0.8m to 1.2m
(2.7 to 4ft).
Ensure the sensor can be
mounted on a perpendicular
wall or pole that would make
its detection pattern parallel
to the ground.
Parallel
2 Prepare the Sensor for Mounting
1. Remove the Cover by pulling from bottom.
2. Remove Detector from the Back Box by pulling from top.