HP BladeSystem c3000 Quickspecs
Download Quickspecs of HP BladeSystem c3000 Enclosure, Server for Free or View it Online on All-Guides.com.
HP NC512m Dual Port 10GbE Multifunction BL-c Adapter
NOTE:
NOTE: NOTE:
NOTE:
An NC512m network adapter card is required for each server blade
connecting to the HP 10Gb Ethernet BL-c Switch
NOTE:
NOTE: NOTE:
NOTE:
A maximum of one NC512m is supported per server in a type II mezzanine
slot.
NOTE:
NOTE: NOTE:
NOTE:
The NC512m requires a minimum of 4 GB of server memory and supports a
maximum of 32 GB. Therefore, when an NC512m is installed in a blade server, the
server is limited to a maximum of 32 GB of memory.
440910-B21
HP BladeSystem
HP BladeSystemHP BladeSystem
HP BladeSystem
c-Class FC SAN
c-Class FC SANc-Class FC SAN
c-Class FC SAN
Interconnects
InterconnectsInterconnects
Interconnects
HP 4Gb Virtual Connect Fibre Channel Module for c-Class BladeSystem
409513-B21
16 port FC Pass-thru Module for c-Class BladeSystem
403626-B21
HP Brocade 4/12 SAN Switch
AE370A
HP Brocade 4/24 SAN Switch Power Pack
AE371A
HP Brocade 4/24 SAN Switch
AE372A
HP Brocade 4/12 SAN Switch Upgrade LTU
AE373A
Cisco MDS 9124e 12 port Fabric Switch
AG641A
HP BladeSystem
HP BladeSystemHP BladeSystem
HP BladeSystem
InfiniBand Interconnects
InfiniBand InterconnectsInfiniBand Interconnects
InfiniBand Interconnects
HP 4X DDR IB Switch Module for HP c-Class BladeSystem
410398-B21
Step 4: Select rack power distribution for installing the enclosure into a rack.
Step 4: Select rack power distribution for installing the enclosure into a rack.Step 4: Select rack power distribution for installing the enclosure into a rack.
Step 4: Select rack power distribution for installing the enclosure into a rack.
NOTE:
NOTE:NOTE:
NOTE:
For use with the c3000 rack-able model only.
NOTE:
NOTE: NOTE:
NOTE:
A pair of PDUs must be ordered for AC Feed redundancy. If AC redundancy is not required, a single PDU or UPS may be
acceptable.
HP Monitored Power
HP Monitored PowerHP Monitored Power
HP Monitored Power
Distribution Unit
Distribution UnitDistribution Unit
Distribution Unit
HP 8.6 kVA Monitored PDU, 30A
AF504A
HP Modular PDU
HP Modular PDUHP Modular PDU
HP Modular PDU
HP 8.3kVA Modular Distribution Unit 40 Amp
252663-D73
HP 4.9kVA Modular Distribution Unit 24 Amp
252663-D72
HP Two C-13 PDU Extension Bars
AF500A
HP UPS
HP UPSHP UPS
HP UPS
HP rack-mountable R5500 UPS (5000VA / 4500 watts)
AF426A
NOTE:
NOTE: NOTE:
NOTE:
The R5500 includes four c-13 PDU Extension bars.
NOTE:
NOTE: NOTE:
NOTE:
The R5500 supports 4 power supplies in the Power Supply Redundant (N+1) power mode.
Step 5: Select Wall Outlet Power Cords
Step 5: Select Wall Outlet Power Cords Step 5: Select Wall Outlet Power Cords
Step 5: Select Wall Outlet Power Cords
(For connection to standard wall outlets)
NOTE:
NOTE: NOTE:
NOTE:
Select one wall outlet power cord for each power supply when plugging the power supplies into a wall outlet.
NOTE:
NOTE: NOTE:
NOTE:
Wall Outlet power cords should only be used with low-line (100v to 110V) power sources. If high-line power outlets are
required, safety regulations require the use of a PDU or a UPS between the c3000 enclosures power supplies and wall outlets.
NOTE:
NOTE: NOTE:
NOTE:
A standard PDU power cord(c13 to C14) is included with each AC power supply, so these wall outlet power cords are not
required if you plan to plug the power supplies into a PDU or UPS.
Wall Outlet Power Cords
Wall Outlet Power CordsWall Outlet Power Cords
Wall Outlet Power Cords
Nema 5-15P to IEC320-C13, low voltage (6 ft/2 m)
NOTE:
NOTE:NOTE:
NOTE:
HP Power cord (6 ft) 1.83 meter 10A C-13-UL domestic power cord, for
grounded USA 110V wall outlets.
AF556A
QuickSpecs
HP BladeSystem c3000 Enclosure
HP BladeSystem c3000 EnclosureHP BladeSystem c3000 Enclosure
HP BladeSystem c3000 Enclosure
Configuration Information Factory Integrated Models
DA - 12790 North America — Version 7 — February 11, 2008