HP ProLiant DL120 Quickspecs

Download Quickspecs of HP ProLiant DL120 Home Theater Server, Server for Free or View it Online on All-Guides.com.

Brand: HP

Category: Home Theater Server , Server

Type: Quickspecs for HP ProLiant DL120

Pages: 39

Download HP ProLiant DL120 Quickspecs

HP ProLiant DL120 Quickspecs - Page 1
1
HP ProLiant DL120 Quickspecs - Page 2
2
HP ProLiant DL120 Quickspecs - Page 3
3
HP ProLiant DL120 Quickspecs - Page 4
4
HP ProLiant DL120 Quickspecs - Page 5
5
HP ProLiant DL120 Quickspecs - Page 6
6
HP ProLiant DL120 Quickspecs - Page 7
7
HP ProLiant DL120 Quickspecs - Page 8
8
HP ProLiant DL120 Quickspecs - Page 9
9
HP ProLiant DL120 Quickspecs - Page 10
10
HP ProLiant DL120 Quickspecs - Page 11
11
HP ProLiant DL120 Quickspecs - Page 12
12
HP ProLiant DL120 Quickspecs - Page 13
13
HP ProLiant DL120 Quickspecs - Page 14
14
HP ProLiant DL120 Quickspecs - Page 15
15
HP ProLiant DL120 Quickspecs - Page 16
16
HP ProLiant DL120 Quickspecs - Page 17
17
HP ProLiant DL120 Quickspecs - Page 18
18
HP ProLiant DL120 Quickspecs - Page 19
19
HP ProLiant DL120 Quickspecs - Page 20
20
HP ProLiant DL120 Quickspecs - Page 21
21
HP ProLiant DL120 Quickspecs - Page 22
22
HP ProLiant DL120 Quickspecs - Page 23
23
HP ProLiant DL120 Quickspecs - Page 24
24
HP ProLiant DL120 Quickspecs - Page 25
25
HP ProLiant DL120 Quickspecs - Page 26
26
HP ProLiant DL120 Quickspecs - Page 27
27
HP ProLiant DL120 Quickspecs - Page 28
28
HP ProLiant DL120 Quickspecs - Page 29
29
HP ProLiant DL120 Quickspecs - Page 30
30
HP ProLiant DL120 Quickspecs - Page 31
31
HP ProLiant DL120 Quickspecs - Page 32
32
HP ProLiant DL120 Quickspecs - Page 33
33
HP ProLiant DL120 Quickspecs - Page 34
34
HP ProLiant DL120 Quickspecs - Page 35
35
HP ProLiant DL120 Quickspecs - Page 36
36
HP ProLiant DL120 Quickspecs - Page 37
37
HP ProLiant DL120 Quickspecs - Page 38
38
HP ProLiant DL120 Quickspecs - Page 39
39
System Unit
System UnitSystem Unit
System Unit
Dimensions
DimensionsDimensions
Dimensions
(H x W x D)
(with bezel)
4.32 x 44.81 x 70.0 mm (1.69" x 17.64" x 27.56")
Weight
WeightWeight
Weight
(approximate)
Maximum
(four hard drives, power
supply, and processor
installed)
31.49 lb (14.3kg)
Minimum
(one hard drive, power
supply, and processor
installed)
28.2lb (12.8kg)
Input Requirements
Input RequirementsInput Requirements
Input Requirements
(per power supply)
Range Line Voltage
90 - 132 VAC,
180 - 264 VAC
Rated Input Current
6 A (at 100 VAC),
3 A (at 200 VAC)
Rated Input Frequency
47 to 63 Hz
Rated Input Power
<550W (at 100 VAC)
550W (at 200 VAC)
BTU Rating
BTU RatingBTU Rating
BTU Rating
Maximum
1314 BTU/hr (at 100 VAC),
1314 BTU/hr (at 200 VAC)
Power Specifications
Power SpecificationsPower Specifications
Power Specifications
To review typical system power ratings use the Power Advisor which is
available via the online tool located at URL:
www.hp.com/go/proliant-
energy-efficient
or
www.hp.com/go/hppoweradvisor
- Click on the system of interest. Example: DL120 G6
- Follow the instructions of the next screens.
Power Supply Output
Power Supply OutputPower Supply Output
Power Supply Output
(per power supply)
Rated Steady-State Power
400 W (at 100 VAC),
400 W (at 200 VAC)
Maximum Peak Power
430 W (at 100 VAC),
430 W (at 200 VAC)
System Inlet Temperature
System Inlet TemperatureSystem Inlet Temperature
System Inlet Temperature
Operating
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if operating
with a fan fault or above 30°C (86°F).
Non-operating
-30° to 65°C (-22° to 149°F). Maximum rate of
change is 20°C/hr (36°F/hr).
Relative Humidity
Relative HumidityRelative Humidity
Relative Humidity
(non-condensing)
Operating
10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-
condensing.
Non-operating
5 to 95% relative humidity (Rh), 38.7°C
(101.7°F) maximum wet bulb temperature, non-
condensing.