Syntax alertentries -T system:mm[x] -recipient-number <-f filter-type> <-n recipient-name>
<-status (on | off)> <-t snmp>
Release Information Command supported by Junos OS Release 9.1 and later.
Description (JCS management module CLI) Display or configure the recipients of SNMP alerts
generated by the JCS management module.
Options -T system:mm[x]—Specify a JCS management module as the command target. Replace
x with the primary management module number (1 or 2).
-recipient-number—Create or specify an alert recipient. Each alert recipient you create
must have a unique number (1 through 12).
-f filter-type—(Optional) Filter the type of alerts received by the alert recipient. Replace
filter-type with a value of critical (receive critical alerts only) or none (no filtering, receive
all alerts).
-n recipient-name—(Optional) Specify the name of the alert recipient. Recipient names
can be up to 31 characters in length. The name can include any character (including
spaces), except for less than (<) and greater than (>) symbols.
-status (on | off)—(Optional) Set alert status for the specified alert recipient. When the
status is on, the recipient receives alarm notifications. When the status is off, the recipient
does not receive alarm notifications.
-t snmp—(Optional) Sets SNMP as the alert notification method for the specified alert
recipient.
Required Privilege
Level
operator (display)
supervisor (display or configure)
Related
Documentation
Configuring SNMP Traps on page 43•
• monalerts on page 69
• snmp on page 74
List of Sample Output alertentries (Display) on page 55
alertentries (Configure) on page 55
Output Fields Table 6 on page 54 lists the output fields for the alertentries command. Output fields are
listed in the approximate order in which they appear.
Table 6: alertentries Output Fields
Field DescriptionField Name
Alert status for the specified recipient. Alert status is on or off.-status
Copyright © 2010, Juniper Networks, Inc.54
JUNOS 10.4 Protected System Domain Configuration Guide