Kenmore N8MSL0701412A1 Installation Instructions Manual

Download Installation instructions manual of Kenmore N8MSL0451408A1 Furnace for Free or View it Online on All-Guides.com. This version of Kenmore N8MSL0451408A1 Manual compatible with such list of devices, as: N8MSL0451412A1, N8MSL0701412A1, N8MSL1102122A1, N8MSN0451408A1, N8MSN0701412A1

Kenmore N8MSL0451408A1 Installation instructions manual - Page 1
1
Kenmore N8MSL0451408A1 Installation instructions manual - Page 2
2
Kenmore N8MSL0451408A1 Installation instructions manual - Page 3
3
Kenmore N8MSL0451408A1 Installation instructions manual - Page 4
4
Kenmore N8MSL0451408A1 Installation instructions manual - Page 5
5
Kenmore N8MSL0451408A1 Installation instructions manual - Page 6
6
Kenmore N8MSL0451408A1 Installation instructions manual - Page 7
7
Kenmore N8MSL0451408A1 Installation instructions manual - Page 8
8
Kenmore N8MSL0451408A1 Installation instructions manual - Page 9
9
Kenmore N8MSL0451408A1 Installation instructions manual - Page 10
10
Kenmore N8MSL0451408A1 Installation instructions manual - Page 11
11
Kenmore N8MSL0451408A1 Installation instructions manual - Page 12
12
Kenmore N8MSL0451408A1 Installation instructions manual - Page 13
13
Kenmore N8MSL0451408A1 Installation instructions manual - Page 14
14
Kenmore N8MSL0451408A1 Installation instructions manual - Page 15
15
Kenmore N8MSL0451408A1 Installation instructions manual - Page 16
16
Kenmore N8MSL0451408A1 Installation instructions manual - Page 17
17
Kenmore N8MSL0451408A1 Installation instructions manual - Page 18
18
Kenmore N8MSL0451408A1 Installation instructions manual - Page 19
19
Kenmore N8MSL0451408A1 Installation instructions manual - Page 20
20
Kenmore N8MSL0451408A1 Installation instructions manual - Page 21
21
Kenmore N8MSL0451408A1 Installation instructions manual - Page 22
22
Kenmore N8MSL0451408A1 Installation instructions manual - Page 23
23
Kenmore N8MSL0451408A1 Installation instructions manual - Page 24
24
Kenmore N8MSL0451408A1 Installation instructions manual - Page 25
25
Kenmore N8MSL0451408A1 Installation instructions manual - Page 26
26
Kenmore N8MSL0451408A1 Installation instructions manual - Page 27
27
Kenmore N8MSL0451408A1 Installation instructions manual - Page 28
28
Kenmore N8MSL0451408A1 Installation instructions manual - Page 29
29
Kenmore N8MSL0451408A1 Installation instructions manual - Page 30
30
Kenmore N8MSL0451408A1 Installation instructions manual - Page 31
31
Kenmore N8MSL0451408A1 Installation instructions manual - Page 32
32
Kenmore N8MSL0451408A1 Installation instructions manual - Page 33
33
Kenmore N8MSL0451408A1 Installation instructions manual - Page 34
34
Kenmore N8MSL0451408A1 Installation instructions manual - Page 35
35
Kenmore N8MSL0451408A1 Installation instructions manual - Page 36
36
Kenmore N8MSL0451408A1 Installation instructions manual - Page 37
37
Kenmore N8MSL0451408A1 Installation instructions manual - Page 38
38
Kenmore N8MSL0451408A1 Installation instructions manual - Page 39
39
Kenmore N8MSL0451408A1 Installation instructions manual - Page 40
40
Kenmore N8MSL0451408A1 Installation instructions manual - Page 41
41
Kenmore N8MSL0451408A1 Installation instructions manual - Page 42
42
Kenmore N8MSL0451408A1 Installation instructions manual - Page 43
43
Kenmore N8MSL0451408A1 Installation instructions manual - Page 44
44
Kenmore N8MSL0451408A1 Installation instructions manual - Page 45
45
Kenmore N8MSL0451408A1 Installation instructions manual - Page 46
46
Kenmore N8MSL0451408A1 Installation instructions manual - Page 47
47
These instructions must be read and understood completely before attempting installation.
Signal Words on Product Labeling
Safety Labeling and Signal Words
DANGER, WARNING, CAUTION, and NOTE Signal Words in Manuals
The signal words DANGER, WARNING, CAUTION, and NOTE The signal word WARNING isused throughout this manual inthe
are used to identify levels of hazard seriousness. The signal word following manner:
DANGER is only used on product labels to signify an immediate
hazard. The signal words WARNING, CAUTION, and NOTE will
be used on product labels and throughout this manual and other The signal word CAUTION is used throughout this manual in the
manual that may apply to the product, following manner:
DANGER - Immediate hazards which will result in severe person-
at injury or death.
WARNING - Hazards or unsafe practices which could result in
severe personal injury or death.
Signal words are used in combination with colors and/or pictures
CAUTION - Hazards or unsafe practices which may result in or product labels.
minor personal injury or product or property damage.
NOTE - Used to highlight suggestions which wilt result in en- z_ Safety-alert symbol
hanced installation, reliability, or operation. When you see this symbol on the unit and in instructions or manu-
als, be alert to the potential for personal injury.
TABLE OF CONTENTS
DIMENSIONS ............................................... 3
SAFETY CONSIDERATIONS .................................. 3
INTRODUCTION ............................................ 4
CODES AND STANDARDS ................................... 5
SAFETY ................................................ 5
GENERAL INSTALLATION ................................ 5
COMBUSTION AND VENTILATION AIR ..................... 5
DUCT SYSTEMS ........................................ 5
ACOUSTICAL LINING AND FIBROUS GLASS DUCT ......... 5
GAS PIPING AND GAS PIPE PRESSURE TESTING .......... 5
ELECTRICAL CONNECTIONS ............................ 5
VENTING .............................................. 5
ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS ........... 5
LOCATION ................................................. 6
AIR FOR COMBUSTION AND VENTILATION .................... 7
INSTALLATION .............................................. 10
UPFLOW INSTALLATION ................................. 10
DOWNFLOW INSTALLATION ............................. 11
FILTER ARRANGEMENT ................................. 12
AIR DUCTS ............................................. 13
AIR DELIVERY - CFM .................................... 14
ELECTRICAL CONNECTIONS ............................ 20
115-V WIRING .......................................... 20
J-BOX RELOCATION .................................... 20
ELECTRICAL CONNECTION TO J-BOX .................... 20
ELECTRICAL DATA ...................................... 21
24-V WIRING ........................................... 22
ACCESSORIES ......................................... 22
VENTING .................................................. 23
GENERAL VENTING REQUIREMENTS ..................... 23
MASONRY CHIMNEY REQUIREMENTS .................... 24
APPLIANCE APPLICATION REQUIREMENTS ............... 26
ADDITIONAL VENTING REQUIREMENTS .................. 26
SIDEWALL VENTING .................................... 27
START-UP, ADJUSTMENT, AND SAFETY CHECK ............... 30
GENERAL .............................................. 30
START-UP PROCEDURES ............................... 30
ADJUSTMENTS ......................................... 31
SPEED SELECTION ..................................... 32
CHECK SAFETY CONTROLS ............................. 33
CHECKLIST ............................................ 34
ORIFICE SIZE AND MANIFOLD PRESSURE ................ 35
SERVICE AND MAINTENANCE PROCEDURES ................. 39
CARE AND MAINTENANCE ................................... 39
SEQUENCE OF OPERATION ................................. 43
WIRING DIAGRAM .......................................... 44
TROUBLESHOOTING GUIDE ................................. 45
IS09001
Use of the AHRI Certified TM Mark indicates
a manufacturer's participation in the program.
For verification of certification for individual
products, go to www.ahridirectory.org .
PERSONAL INJURY, AND/OR PROPERTY
DAMAGE HAZARD
Failure to carefully read and follow this warning could
result in equipment malfunction, property damage,
3ersonal injury and/or death.
Installation or repairs made by unqualified persons
could result in equipment malfunction, property
damage, personal injury and/or death.
The information contained in this manual is intended for
use by a qualified service technician familiar with safety
3rocedures and equipped with proper tools and test
instruments.
Installation must conform with local building codes and
with the Natural Fuel Gas Code (NFCG) NFPA
54/ANSI Z223.1, and National standards of Canada
CAN/CSA-B149.1 and .2 Natural Gas and Propane
Installation Codes.
INSTALLER: Affix these instructions on or adjacent to the furnace.
CONSUMER: Retain these instructions for future reference.
Portions ofthe text and tables are reprintedfrom NFPA 54/ANSI Z223.t -20096), with permission of National Fire Protection Association, Quincy, MA 02269 and American Gas Association, Washing-
ton, DC 20001. This reprinted material is not the complete and official position of the NFPA or ANSI, on the referenced subiect, which is represented only by the standard in its entirety,
PrintedinU.S.A. 441 01 1402 02 May. 2012