Lennox EST-36 Specification

Download Specification of Lennox EST-36 Indoor Fireplace for Free or View it Online on All-Guides.com.

Lennox EST-36 Specification - Page 1
1
Lennox EST-36 Specification - Page 2
2
Appliance Specifications
Hearth Extension Dimensions
Page 1 of 2
4-3/4"
(121mm)
3-1/4"
(83mm)
18" (457mm)
Min. Distance to
Unprotected Side Wall
12" (305mm)
Min. Distance to
Protected Side Wall
Fireplace
1/2"
(13mm)
Combustible
materials allowed
in shaded Areas
15" O.D.
(381 mm)
Front View
H
J
K
A
R
Left Side
F
P
G
Right Side
G
F
L
M
Top View
D
C
B
E
Fireplace
Opening
EST-36 & EST-42:
6-9/16" (167mm)
EST-50:
10" (254mm)
12"
(305mm)
Min.
Combustible
Mantel
and Trim
Spacer
Noncombustible
Wall Covering
Finished
Wall
12"
(305mm)
Max.
1-1/2" (38mm)
A
B
D
C
C
M
L
Note: Outside air kit
installs on LEFT side
for EST-36 & EST-42.
Note: Outside air kit
installs on RIGHT
side for EST-50.
N
Q
Model No. A B C D E F G H
EST-36
& EST-42
in. 42-9/16 47-7/8 28-9/16 37-1/4 11 66-1/16 47-1/8 36 / 42
mm 1081 1216 725 946 279 1678 1197 914 / 1067
EST-50
in. 53-1/4 59-1/2 29-5/8 44-5/8 14-1/4 84 61-7/8 50
mm 1353 1511 753 1133 362 2134 1572 1270
Model No. J K L M N P Q R
EST-36
& EST-42
in.
29 6 (36”) / 3 (42”) 10-1/2 8-3/4 13 12 7
mm 737 152 (36”) / 76 (42”) 267 222 330 305 178
EST-50
in. 36 4-3/4 15 10 10-5/8 11-1/8 8-1/2
mm 914 121 381 254
270 283
216
6-9/16
167
8-9/16
218
LENNOX
ESTATE
SERIES WOOD BURNING FIREPLACES
EST-36 / EST-42 / EST-50
P/N 506035-35 Rev. A 03/2011
Note:
Diagrams, illustrations, and photographs are
not to scale; consult fireplace Installation
Instructions.
Product designs, materials, dimensions,
specifications, colors, and prices are subject
to change or discontinuance without notice.
EST-50 models are not sold in Canada.
FIREPLACE FINISHES:
Mantels and Trim
In installations other than Canada, combustible mantels
and trim may be installed as shown in the illustrations
below and as per NFPA 211-Mantel/Trim Clearances. If a
mantel is of a noncombustible material, it is exempt from
these requirements as long as it does NOT interfere with
the installation or operation of glass doors.
For combustible mantel and trim specifications in
Canadian installations (EST-36 and EST-42 only), see
the fireplace Installation Instructions.
FIREPLACE FINISHES:
Vertical Surround Limitations
Combustible materials may project beyond the sides
of the fireplace opening as long as they are kept
within the shaded area illustrated below.
FIREPLACE FINISHES:
Hearth Extensions and Wall Shields
A hearth extension must be installed with all
fireplaces. Its purpose is twofold: 1) to protect a
combustible floor in front of the fireplace from
both radiant heat and sparks; and 2) to distinguish
the prescribed hearth extension area from other
unprotected surfaces.
Models A B C D
EST-36
20"
(508mm)
36"
(914mm)
12"
(305mm)
60"
(1524mm)
EST-42
20"
(508mm)
42"
(1066mm)
12"
(305mm)
60"
(1524mm)
EST-50
20"
(508mm)
50"
(1270mm)
12"
(305mm)
74"
(1880mm)
Wall shield
required if
less than
18" (457mm).
40"
(1016mm)
40"
(1016mm)
C
C
B
A
15
°
Typical U.S. Installation