FEATURES
Leviton's Decora
®
Style design Power interruption less than 10 seconds, dimmer remains in existing state
Soft fade ON/OFF w/inside rocker function ON/OFF LED indicates status of load
Minimum Brightness Adjustment Color conversion available
Brightness Level Display
FCC COMPLIANCE STATEMENT
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device must not
cause harmful interference, and (2) This device must accept any interference received, including interference that may cause
undesired operation.
INSTALLATION INSTRUCTIONS
WARNING: TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH APPROPRIATE ELECTRICAL CODES AND
REGULATIONS.
WARNING: IF YOU ARE NOT SURE ABOUT ANY PART OF THESE INSTRUCTIONS, CONSULT A QUALIFIED ELECTRICIAN.
WARNING: TO AVOID OVERHEATING AND POSSIBLE DAMAGE TO THIS DEVICE AND OTHER EQUIPMENT, DO NOT
INSTALL TO CONTROL A RECEPTACLE, FLUORESCENT LIGHTING, OR A MOTOR - OR TRANSFORMER - OPERATED
APPLIANCE OTHER THAN APPROPRIATE LOW-VOLTAGE LIGHTING.
CAUTION (For Incandescent Only): USE WITH INCANDESCENT OR 120V HALOGEN FIXTURES ONLY.
CAUTION (For Magnetic Low-Voltage Only):
1. USE WITH MAGNETIC LOW-VOLTAGE TRANSFORMERS, INCANDESCENT, OR 120V HALOGEN FIXTURES ONLY. USE A
LEVITON ELECTRONIC LOW-VOLTAGE DIMMER TO CONTROL ELECTRONIC (SOLID STATE) LOW-VOLTAGE
TRANSFORMERS.
2. WHEN A MAGNETIC LOW-VOLTAGE CIRCUIT IS OPERATED AT A DIM LEVEL, WITH ALL LAMPS INOPERATIVE, EXCESS
CURRENT MAY FLOW THROUGH THE TRANSFORMER. TO AVOID POSSIBLE TRANSFORMER FAILURE DUE TO
OVERCURRENT, USE A TRANSFORMER THAT INCORPORATES THERMAL PROTECTION OR A FUSE AT THE PRIMARY
WINDINGS.
OTHER CAUTIONS:
1. USE ONLY ONE (1) DIMMER PER LOAD. FOR REMOTE OPERATION, USE THE LEVITON REMOTE, CAT. NO. MS
ØØ
R-1.
DO NOT USE A 3-WAY SWITCH.
2. DISCONNECT POWER WHEN SERVICING OR CHANGING BULBS.
3. USE THIS DEVICE ONLY WITH COPPER OR COPPER CLAD WIRE. WITH ALUMINUM WIRE USE ONLY DEVICES
MARKED CO/ALR OR CU/AL.
MULTI-GANG INSTALLATION:
When ganging dimmers, the side sections of the mounting strap
must be removed. Use pliers to carefully bend side sections back
and forth until they break off (see Figure 1). The side sections
dissipate heat, so removing them requires a derating of the
dimmer's capacity (see chart).
MAXIMUM BULB WATTAGE (For Magnetic Low-Voltage Only):
Low-voltage dimmers are rated in Volt-Amps (VA). The maximum
bulb wattage is determined by the efficiency of the transformer in
the low-voltage lighting system. Transformer efficiencies will vary
from different manufacturers; consider 75% efficient as average.
Use the chart to determine maximum bulb wattage for typical
transformer efficiency ratings.
TO INSTALL:
1
. WARNING: TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF
POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT
POWER IS OFF BEFORE WIRING!
2. Remove existing wallplate and switch or dimmer, if applicable.
3. Remove 3/4" (1.9 cm) of insulation from each circuit conductor.
Make sure that ends of conductors are straight.
4. Connect lead wires per appropriate WIRING DIAGRAM as
follows:
WARNING: CONNECT A MAGNETIC LOW-VOLTAGE
DIMMER ONLY TO THE PRIMARY (HIGH-VOLTAGE) SIDE OF
A MAGNETIC LOW-VOLTAGE TRANSFORMER. Twist strands
of each lead tightly and, with circuit conductors, push firmly into
appropriate wire connector. Screw connectors on clockwise
making sure that no bare conductor shows below the wire
connectors. Secure each connector with electrical tape.
NOTE: For single pole applications, cap YELLOW lead with an
appropriate size wire connector. Secure connector with electrical
tape.
5. Carefully position all wires to provide room in outlet box for
dimmer. Mount dimmer into box with mounting screws supplied.
6. Restore power at circuit breaker or fuse. Turn the dimmer ON by
pressing the upper half of the rocker. The GREEN ON/OFF LED
will turn OFF to indicate power to the dimmer (when the dimmer
is OFF, the LED is ON).
PK-92966-10-00-0A
For Technical Assistance Call:
1-800-824-3005 (U.S.A. Only)
1 800 405-5320 (Canada Only)
www.leviton.com
LIMITED 2 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not
for the benefit of anyone else that this product at the time of its
sale by Leviton is free of defects in materials and workmanship
under normal and proper use for two years from the purchase
date. Leviton’s only obligation is to correct such defects by
repair or replacement, at its option, if within such two year
period the product is returned prepaid, with proof of purchase
date, and a description of the problem to Leviton
Manufacturing Co., Inc., Att: Quality Assurance
Department, 59-25 Little Neck Parkway, Little Neck, New
York 11362-2591 (In Canada send to Leviton Mfg. of Canada
Ltd., 165 Hymus Blvd., Point Claire, (Quebec), Canada H9R
1E9). This warranty excludes and there is disclaimed liability
for labor for removal of this product or reinstallation. This
warranty is void if this product is installed improperly or in an
improper environment, overloaded, misused, opened, abused,
or altered in any manner, or is not used under normal operating
conditions or not in accordance with any labels or instructions.
There are no other or implied warranties of any kind, including
merchantability and fitness for a particular purpose, but if any
implied warranty is required by the applicable jurisdiction, the
duration of any such implied warranty, including merchantability
and fitness for a particular purpose, is limited to two years.
Leviton is not liable for incidental, indirect, special, or
consequential damages, including without limitation, damage
to, or loss of use of, any equipment, lost sales or profits or
delay or failure to perform this warranty obligation. The
remedies provided herein are the exclusive remedies under
this warranty, whether based on contract, tort or otherwise.
PK-92966-10-00-0A
C O L L E C T I O N B Y L E V I T O N
Two More than
Rating Single Gang
2 Gang
600VA 450W 375W 300W
1000VA 750W 600W 525W
MAXIMUM BULB WATTAGE AT 75% EFFICIENCY
Large
Upper
Rocker
Small
Upper
Rocker
Small
Lower
Rocker
Air Gap
Switch
ON/OFF
LED
Large
Lower
Rocker
Minimum Brightness
Adjustment Switch
Mounting Strap
Side Sections
Figure 1 - Dimmer Functions
Two More than
Cat. No. Single Gang
2 Gang
MLI06-1 600W 500W 400W
MLI10-1 1000W 800W 700W
MLM06-1 600VA 500VA 400VA
MLM10-1 1000VA 800VA 700VA
MAXIMUM LOAD PER DIMMER FOR MULTI-GANG
/
/
/
/
Single Pole (One location) or
3-Way (Multi-location)
120VAC, 60Hz
Incandescent
Cat. No. MLI
Ø
6-1, 600W
(w/brightness level display)
Cat. No. MLI1
Ø
-1, 1000W
(w/brightness level display)
Magnetic Low-Voltage
Cat. No. MLM
Ø
6-1, 600VA
(w/brightness level display)
Cat. No. MLM1
Ø
-1, 1000VA
(w/brightness level display)
Total minimum wattage must
exceed 40W and 40VA
For use w/ Cat. No. MS
ØØ
R-1 Multi-Remote™
INSTALLATION INSTRUCTIONS
L S
L
S
PK-92966-10-00-0A 6/16/00, 1:53 PM1