Leviton RZCZ1 Installation Instructions

Download Installation instructions of Leviton RZCZ1 Switch for Free or View it Online on All-Guides.com.

Brand: Leviton

Category: Switch

Type: Installation instructions for Leviton RZCZ1

Pages: 2

Download Leviton RZCZ1 Installation instructions

Leviton RZCZ1 Installation instructions - Page 1
1
Leviton RZCZ1 Installation instructions - Page 2
2
WARNINGS AND CAUTIONS:
ON/OFF LED for remote load control.
To be installed and/or used in accordance with appropriate electrical codes and regulations.
If you are unsure about any part of these instructions, consult a qualified electrician.
Vizia™ RF RZCZ4 remote does not control the load, but provides scene applications to operate with Vizia
TM
RF switches.
Recommended minimum wall box depth is 2-1/2".
WARNINGS AND CAUTIONS:
Can call up four (4) zone ON/OFF with advanced Programmer/Remote (see RZCPG).
Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.
Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL.
4-Zone Controller
Cat. No. RZCZ4
120VAC, 60Hz
INSTALLATION INSTRUCTIONS
DI-000-RZCZ4-00A-X1
Tools needed to install your 4-Zone Controller:
Slotted/Phillips Screwdriver Electrical Tape Pliers
Pencil Cutters Ruler
Changing the color of your 4-Zone Controller:
Your 4-Zone controller includes three color options. The controller ships
with the White frame attached. To change color of frame, proceed as
follows:
Line up tabs
and press in
side to attach
Push in
side at tab
to release
/./&&
/./&&
/./&&
/./&&
/./&&
/./&&
/./&&/./&&
/./&&
/./&&
/./&&
/./&&
WARNING: TO AVOID FIRE, SHOCK OR DEATH; TURN
OFF POWER at circuit breaker or fuse and test that power is off
before wiring!
Step 1
Compatible with enabled products!
TM
Step 3
Preparing and connecting wires:
This 4-Zone controller can be wired using side wire terminal
screws or through backwire openings. Choose appropriate wire
stripping specifications accordingly.
Make sure that the ends of the wires from the wall box are
straight (cut if necessary).
Side Wire Connection
Side wire terminals accept
#14 AWG
solid wire copper only.
5/8"
(1.6 cm)
Strip Gage
(measure bare
wire here)
Cut
(if necessary)
Back Wire (either hole may be used)
Back wire openings use #14-12 AWG
solid wire copper only.
Programmer/Remote
Cat. No. RZCPG
1 ON
2 ON
3 ON
4 ON
OFF
OFF
OFF
OFF
Menu
Button
Center
Button
WIRING SWITCH:
Connect wires per WIRING DIAGRAM as follows:
Green or bare copper wire in wall box to Green terminal screw.
Line Hot wall box wire to terminal screw marked "BK".
Line Neutral wall box wire to terminal screw marked "WH".
Hot (Black)
Neutral (White)
Line
120VAC, 60Hz
BKWH
Green
Ground
4-Zone Controlller
Wiring Application:
Step 4
Identifying your wiring application (most common):
NOTE: If the wiring in your wall box does not resemble this
configuration, consult a qualified electrician.
Step 2
INTRODUCTION
Leviton’s Vizia
TM
RF components are designed to communicate with
each other via Radio Frequency (RF) to provide remote control of your
lighting. Using RF technology allows Leviton to provide the greatest
signal integrity possible. Each module in Leviton’s Vizia
TM
RF component
line is a Z-Wave
TM
enabled device. In a Z-Wave
TM
network, each device
is designed to act as a router. These routers will re-transmit the RF signal
from one device to another until the intended device is reached. This
ensures that the signal is received by its intended device by routing the
signal around obstacles and radio dead spots. The 4-Zone Controller
is compatible with any Z-Wave™ enabled network, regardless of the
manufacturer and can also be used with other devices displaying the
Z-Wave™ logo.
This is a Z-Wave™ Controller
Zone/Area control without traveler wires
Can control ON/OFF dim/bright for up to 4 Zones/Area.
ON/OFF LED
Two way communication
RF reliability
Ease of installation – No new wiring
Compatible with other Z-Wave™ enabled devices
FEATURES
Step 6
Including 4-Zone Controller into Z-Wave
TM
Network:
NOTES:
If using a non-Leviton Programmer/Remote, refer to the Programmer/
Remote instruction sheet.
4-Zone controllers incuded into a Z-Wave
TM
network must be updated
after you have included all other devices.
A) If using a Leviton Z-Wave
TM
Programmer/Remote, Cat. No. RZCPG,
press the Menu button and scroll down to System Setup. Press the
center button to select System Setup Menu. Press the center button to
select Network. Press the center button to <Include Node>.
Step 6 cont'd
B) If using RZCPG Programmer/Remote, you will be prompted to place
4-Zone controller into programming mode.
C) To access Program mode, press and hold the
left side of buttons 1 and 3
(refer to figure).
Wait 5 seconds until the LED turns Amber.
Release the button and the LED will blink
Amber. You are now in Programming mode.
NOTE: If the LED on the 4-Zone controller
turns solid Red while including, there has
been a communication error.
D) While standing close to the 4-Zone controller
(approximately 2-5 ft.), press the center button
on the Programmer/Remote to <Include>
device in the network.
NOTE: Only one device
may be included at any time.
E) The Primary Programmer/Remote will assign
a Home ID, Node ID, and Name for this
device.
NOTE: This information will be stored in the Programmer/Remote to
be used for future reference.
NOTE: You may name or edit the node of this device at this time.
F) The 4-Zone controller is now installed in the network.
G) After all devices are included into the network, the controller must
be updated to allow proper network function. To update controller
proceed as follows:
If using a non-Leviton Programmer/Remote, refer to the
Programmer/Remote instruction sheet for updating controller.
If using Leviton Z-Wave
TM
Programmer/Remote, Cat. No. RZCPG,
press the Menu button and scroll down to System Setup. Press
the center button to select System Setup Menu. Press the center
button to select Network. Press the center button to select Update
"cntrl". When prompted, press desired button on 4-Zone controller.
Wait until the RZCPG Programmer/Remote confirms completion.
Update is done.
NOTE: If the 4-Zone controller has been
successfully Included in the network and
the user tries to Include it again without first
excluding it from the network, the controller
will retain the first node ID it had received and
ignore the second.
After frame is removed, remove existing push buttons by pressing out
buttons from back of frame and replace them with desired color change
push buttons by pressing in from front of frame. To make IR capable, use
new DIM/BRIGHT button with IR window.
INSTALLING YOUR 4-ZONE CONTROLLER
NOTE: Use check boxes when Steps are completed.
Restore power at circuit breaker or fuse.
LED should turn ON, when any button is pressed. If LED does not turn
ON, refer to the TROUBLESHOOTING section.
Position all wires to provide room in
outlet wall box for device.
Ensure that the word “TOP” is facing up
on device strap.
Partially screw in mounting screws in
wall box mounting holes.
NOTE: Dress wires with a bend as
shown in diagram in order to relieve
stress when mounting device.
Testing your 4-Zone Controller prior to mounting
in wall box:
Step 5
2
3
1
1. Line (Hot)
2. Neutral
3. Ground