LG LRBP1031W - 10 Cu. Ft. Cabinet Depth Bottom Freezer Refrigerator Owner's Manual

Download Owner's manual of LG LRBP1031NI Refrigerator for Free or View it Online on All-Guides.com. This version of LG LRBP1031NI Manual compatible with such list of devices, as: LRBP1031NI, LRBP1031T, LRBP1031W, LRBP1031W - 10 Cu. Ft. Cabinet Depth Bottom Freezer Refrigerator

LG LRBP1031NI Owner's manual - Page 1
1
LG LRBP1031NI Owner's manual - Page 2
2
LG LRBP1031NI Owner's manual - Page 3
3
LG LRBP1031NI Owner's manual - Page 4
4
LG LRBP1031NI Owner's manual - Page 5
5
LG LRBP1031NI Owner's manual - Page 6
6
LG LRBP1031NI Owner's manual - Page 7
7
LG LRBP1031NI Owner's manual - Page 8
8
LG LRBP1031NI Owner's manual - Page 9
9
LG LRBP1031NI Owner's manual - Page 10
10
LG LRBP1031NI Owner's manual - Page 11
11
LG LRBP1031NI Owner's manual - Page 12
12
LG LRBP1031NI Owner's manual - Page 13
13
LG LRBP1031NI Owner's manual - Page 14
14
LG LRBP1031NI Owner's manual - Page 15
15
LG LRBP1031NI Owner's manual - Page 16
16
LG LRBP1031NI Owner's manual - Page 17
17
LG LRBP1031NI Owner's manual - Page 18
18
LG LRBP1031NI Owner's manual - Page 19
19
LG LRBP1031NI Owner's manual - Page 20
20
LG LRBP1031NI Owner's manual - Page 21
21
LG LRBP1031NI Owner's manual - Page 22
22
LG LRBP1031NI Owner's manual - Page 23
23
LG LRBP1031NI Owner's manual - Page 24
24
LG LRBP1031NI Owner's manual - Page 25
25
LG LRBP1031NI Owner's manual - Page 26
26
LG LRBP1031NI Owner's manual - Page 27
27
LG LRBP1031NI Owner's manual - Page 28
28
LG LRBP1031NI Owner's manual - Page 29
29
LG LRBP1031NI Owner's manual - Page 30
30
LG LRBP1031NI Owner's manual - Page 31
31
LG LRBP1031NI Owner's manual - Page 32
32
LG LRBP1031NI Owner's manual - Page 33
33
SERVICING PRECAUTIONS
Air Recharging in Compressor
Test the refrigeration by connecting it electrically before
refilling operation. It is necessary to ascertain the function
of the meter-compressor and identify the defects
immediately. If defects have been found, empty the old
system of possible R134a residue by breaking off the end
of the extension piece at its narrow point. (Figure 1)
Replace the filter and any damaged components. Unsolder
and pull off the piece remaining inside the service tube and
then attach an complete extension with male Hansen, and
solder it to the same tube again. (Figure 2)
POINT TO BE
BROKEN
SERVICE TUBE EXTENSION
CHARGE TUBE
EXTENSION
MALE HANSEN
SOLDERING POINT
Figure 1 Figure 2
It is necessary to execute the soldering operation with
valve open so that the fumes caused by oil residue can
come out freely without blowholes between two tubes
during the heating of the point to be soldered.
The extension fitted with the male Hansen is connected to
the female fitting of the vacuum pump tube. (Figure 3)
UM
PRESSURE
GAUGE
igure 3
Air evacuating from the system begins as soon as the
pump starts. The refrigeration system must be kept under
vacuum until the reading on the low-pressure gauge
indicates vacuum (0 absolute, -1 atm., -760 mm hg) in any
case it is advisable to keep the pump running for about 30
minutes. (Figure 3)
In case that a considerable leakage occurs it will be
necessary to stop the vaccum pump and to add a small
quantity of Freon to the system, if vacuum should not be
obtained (pressure gauge can't fall to 1 atmosphere), start
the refrigeration unit and find the leakage with the special
leak-finder. When the defective soldering point is visible,
re-do it after opening the extension tube valve and
reestablishing the normal outside pressure inside the
group.
Because the melted alloy is sucked into the tubes and
blocks them, the pressure must be rebalanced when
vacuum is in the system in soldering. As soon as the
vacuum operation is over, add the quantity in grams of
R134a to the refrigeration system. Remember that every
system has an exact quantity of R134a with a tolerance of
+5 grams that can be added. (Figure 4)
q\ i TO TiE R134a CYLINDER
'__ TOsTTHEEMREFRiGEF_lr_ N4
Before performing this operation (if the vacuum pump and
refilling cylinder are connected), make sure that the valve
placed between the vacuum pump and the refilling tube are
closed in order to keep the Freon for addition to the system.
(Figure 5)
FILLING OR VALVE TO BE OPENED
CHARGE TUBE WHEN REFILLING
TO THE REFRIGERATION TO THE CHARGE
SYSTEM CYLINDER
VALVE TO BE CLOSED
AFTER VACUUM
TO THE VACUUM PUMP
Figure 5
In addition, check the graduated scale on the cylinder for
the quantity of R134a to be added, for example, if we have
750 grams of Freon in the cylinder and must add 165
grams to the group, this amount will be reached when R-
134a has dropped to 585 grams, remembering that the
indicator shows a lower limit of meniscus. De this after
choosing the scale corresponding to the gas pressure
different scales reported as the same gas pressure
indicated by the pressure gauge on the top of the column.
To make R134a flow into the system, open the valve
placed at the base of the cylinder and connected to the
filling tube. The amount of Freon cannot be added to the
system all at once because it may cause a blocking of
the motor-compressor. Therefore, proceed by adding the
original quantity of about 20-30 grams and close the valve
immediately.
The pressure rises and the motor compressor must start
sucking the gas and lowering the pressure again.
Regulate the valve again, in the safe way until reaching the
quantity of R134a established for the system being
charged. When the system is running, the suction pressure
must be stabilized between 0.30 to 0.6 atmosphere.
-3-