Lifescan Fast Take Quick Reference Manual

Download Quick reference manual of Lifescan Fast Take Blood Glucose Meter, Other for Free or View it Online on All-Guides.com.

Brand: Lifescan

Category: Blood Glucose Meter , Other

Type: Quick reference manual for Lifescan Fast Take

Pages: 2

Download Lifescan Fast Take Quick reference manual

Lifescan Fast Take Quick reference manual - Page 1
1
Lifescan Fast Take Quick reference manual - Page 2
2
STEP 1
STEP 2
STEP 3
Enter memory mode.
Start with meter turned off.
Press M button. When 14-day
average appears, you are in
memory mode.
Recall test results.
After three seconds, most
recent test result with date
and time appears. Press C but-
ton once and next most recent
test result will appear.
Continue pressing C button to
recall last 150 test results in
order.
Exit memory mode.
Press M button to turn off
meter.
Using the
meter memory
STEP 1
STEP 2
STEP 3
Insert test strip.
Meter turns on automatically.
Apply sample.
Touch blood drop to TOP WHITE
EDGE of test strip. Do not
push your finger against test
strip. Hold blood drop to TOP
WHITE EDGE of test strip until
blood has completely filled con-
firmation window.
Accurate results in just
15 seconds.
Test
summary
©LifeScan, Inc. 2003
Milpitas, CA 95035
10/2003
AW 05266504A
Display symbols
and messages
Blood glucose test result with
suggestion to check ketone levels.
Battery power too low for
testing. Replace batteries
immediately.
Note: Millimoles per litre
(mmol/L) is the standard unit
of measure in Canada. Select
mmol/L whenever you reset
the meter.
Problem with meter.*
Meter electronics problem.*
Blood sample applied
before appeared on
display.*
Test strip damaged,
removed during test, or
inserted improperly.*
* Retest with a new test strip. If
problem persists, call the
OneTouch
®
Customer Care Line at
1 800 663-5521.
Average of last 14 days
(64 tests performed).
Blood glucose level higher
than 33.3 mmol/L (600 mg/dL).
Blood glucose level lower
than 1.1 mmol/L (20 mg/dL).
Temperature too low for testing.
Temperature too high for testing.
Coding
the meter
STEP 1
STEP 2
STEP 3
Code meter before using
it for the first time and
every time you change to
another vial of OneTouch
®
FastTake
®
Test Strips.
Enter code mode.
Start with meter turned off.
Insert OneTouch
®
FastTake
®
Test Strip to turn on meter.
All display segments will
appear followed by date and
time. Code number will
appear next.
Match code numbers.
Compare code number on
meter display with code num-
ber on test strip vial. If they
match, begin testing. If they
do not match, follow Step 3.
Code meter.
Press C button until code
numbers match. After
appears, OneTouch
®
FastTake
®
System is ready for testing.
Note: With clean, dry hands,
you may touch the test strip
anywhere on its surface when
removing it from the vial or
inserting it into the meter.
www.OneTouch.ca
Less Painful Testing / Tests moins douloureux
Quick Reference Guide*
Aide-mémoire*
BEFORE TESTING: See inside for
instructions on coding the meter and
the test procedure.
*Important: Read detailed instructions
in your OneTouch
®
FastTak e
®
Owner’s
Booklet before doing a test.
AVANT D’EFFECTUER UN TEST : Voir à
l’intérieur les instructions de codage
du lecteur de glycémie et la méthode
de test.
*Important : Lire les instructions détail-
lées dans votre Guide d'utilisation du
OneTouch
®
FastTake
®
avant d’effectuer
un test.
DCO_05266504A_OTFT_QRG_CAe_FR 12/10/03 10:35 AM Page 1