Installation°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°
Cobf et f s aff3do
Installing the Chassis into the Cabinet
1. Slide the chassis into the cabinet.
2. To replace the front, place the top of the decorative
front in position and pivot back towards the unit and
snap into place. Replace screws and air filter.
3. Replace the two (2) antitheft screws at the bottom side
of cabinet.
4. Use supplied sealant to fill any minor openings.
5. Make sure unit is OFF, before plugging into the outlet.
Use caution when working around exposed sharp edges
of the cabinet and sharp coils to avoid injury or torn
clothing.
Drafn Instalfadon
Condensate Drain
A condensate drain is provided to divert excess water when
air conditioner is installed over a doorway or sidewalk.
1. Pry cap plug from the condensate drain (located on
underside of bottom pan). Use a 3/8" pipe tap and fully
thread the condensate drain (Fig. S).
2. Screw a 3/8" pipe fitting into the condensate drain. The
fitting should be protruding approximately 1/2" above
the bottom pan when fully threaded into the conden-
sate drain (Fig. T).
3. If an open drain source is used to dispose of conden-
sate, plastic or rubber tubing may be run directly from
the pipe fitting to the open drain source. If closed drain
source (internal structural plumbing) is used, a "P" trap
must be between the 3/8" pipe fitting and the closed
drain source (Fig. U).
Do not remove the cap plug, unless the condensate drain
is used.
OUTSIDE VIEW FROM BOTTOM
Cap plug
3/8" t)ipe fittiug
fiflly threaded into
COIldCIISatP drain
_o {J To closed drain source
P ,,p. trat)