Maytag W10252706B Installation Instructions Manual

Download Installation instructions manual of Maytag AER3311WA Cooktop, Ranges for Free or View it Online on All-Guides.com. This version of Maytag AER3311WA Manual compatible with such list of devices, as: AER5830VA, AER6011VAS, WFE361LVT, WFE371LVB - 5.3 Cubic Foot Electric Range, WFE374LVB

Brand: Maytag

Category: Cooktop , Ranges

Type: Installation instructions manual

Model: Maytag AER3311WA , Maytag AER3311WAW , Maytag AER5522VA , Maytag AER5523XAB , Maytag AER5524XAD , Maytag AER5823XAS , Maytag AER5830VA , Maytag AER5830VAD , Maytag AER5830VAS , Maytag AER5844VA , Maytag AER5844VAS , Maytag AER6011VA , Maytag AER6011VAS , Maytag GFE461LVB - Ceramic Convection Range , Maytag GFE461LVQ - 30 Inch Electric Range , Maytag GFE461LVS - 30" Ing Electric Range , Maytag GFE461LVT - 30 Inch Electric Range , Maytag GFE471LVS , Maytag GFE471LVS - 30" Ing Electric Range , Maytag MER5605WB , Maytag MER7662WB , Maytag MER7662WQ - Ceramic Range , Maytag MER7662WS - Ceramic Range - Stainless , Maytag MER7662WW - 5.3 Cu Ft , Maytag MER7765WB - Ceramic Range , Maytag MER7765WS - Ceramic Range - Stainless , Maytag MER7765WW - 5.3 CF HIDDEN BAKE EVENAIR CONION DELAY KEEP WARM 2 6 , Maytag MER7775WB , Maytag MER7775WS , Maytag MER7775WW , Maytag RF110AXSQ , Maytag RF111PXSQ , Maytag RF114PXSB - 30" STANDARD CLEAN , Maytag RF114PXSQ - Electric , Maytag RF114PXST , Maytag RF212PXSQ , Maytag RF263LXTB - 30in Electric Range , Maytag RF263LXTQ , Maytag RF263LXTS - Electric , Maytag RF263LXTT , Maytag RF264LXSB - 30 Electric Range , Maytag RF264LXSQ , Maytag W10252706B , Maytag WFE115LXB , Maytag WFE115LXQ , Maytag WFE301LVB - 30 Inch Electric Range , Maytag WFE301LVQ , Maytag WFE321LWB , Maytag WFE321LWQ , Maytag WFE321LWS , Maytag WFE324LWB , Maytag WFE324LWQ , Maytag WFE361LVB - 30 Inch Electric Range , Maytag WFE361LVD - Universal 4.8 Cubic Foot Ele , Maytag WFE361LVQ - R 30 in. Ing Electric Range5 , Maytag WFE361LVT , Maytag WFE364LVB , Maytag WFE364LVS , Maytag WFE366LVB , Maytag WFE366LVQ - 30 Inch Electric Range , Maytag WFE366LVS - 30" - Electric Range , Maytag WFE366LVT - 30 IN SC CLEANTOP CERAN5 , Maytag WFE371LVB - 5.3 Cubic Foot Electric Range , Maytag WFE371LVQ , Maytag WFE374LVB , Maytag WFE374LVQ , Maytag WFE374LVS , Maytag WFE381LVB - 30 Inch Electric Range , Maytag WFE381LVQ - 30 Inch Electric Range , Maytag WFE381LVS - 30" Ing Electric Range

Pages: 16

Download Maytag AER3311WA Installation instructions manual

Maytag AER3311WA Installation instructions manual - Page 1
1
Maytag AER3311WA Installation instructions manual - Page 2
2
Maytag AER3311WA Installation instructions manual - Page 3
3
Maytag AER3311WA Installation instructions manual - Page 4
4
Maytag AER3311WA Installation instructions manual - Page 5
5
Maytag AER3311WA Installation instructions manual - Page 6
6
Maytag AER3311WA Installation instructions manual - Page 7
7
Maytag AER3311WA Installation instructions manual - Page 8
8
Maytag AER3311WA Installation instructions manual - Page 9
9
Maytag AER3311WA Installation instructions manual - Page 10
10
Maytag AER3311WA Installation instructions manual - Page 11
11
Maytag AER3311WA Installation instructions manual - Page 12
12
Maytag AER3311WA Installation instructions manual - Page 13
13
Maytag AER3311WA Installation instructions manual - Page 14
14
Maytag AER3311WA Installation instructions manual - Page 15
15
Maytag AER3311WA Installation instructions manual - Page 16
16
5
Electrical Connection
To properly install your range, you must determine the type of
electrical connection you will be using and follow the instructions
provided for it here.
Range must be connected to the proper electrical voltage
and frequency as specified on the model/serial number rating
plate. The model/serial number rating plate is located behind
the control panel or on the oven frame behind the storage
drawer panel. Refer to the figures in the “Product
Dimensions” section of the “Location Requirements” section.
This range is manufactured with the neutral terminal
connected to the cabinet. Use a 3-wire, UL listed, 40- or
50-amp power supply cord (pigtail) (see following Range
Rating chart). If local codes do not permit ground through the
neutral, use a 4-wire power supply cord rated at 250 volts,
40 or 50 amps and investigated for use with ranges.
*The NEC calculated load is less than the total connected load
listed on the model/serial rating plate.
**If connecting to a 50-amp circuit, use a 50-amp rated cord with
kit. For 50-amp rated cord kits, use kits that specify use with a
nominal 1³⁄₈" (34.9 mm) diameter connection opening.
A circuit breaker is recommended.
The range can be connected directly to the circuit breaker
box (or fused disconnect) through flexible or nonmetallic
sheathed, copper or aluminum cable. See the “Electrical
Connection” section.
Allow 2 to 3 ft (61.0 cm to 91.4 cm) of slack in the line so that
the range can be moved if servicing is ever necessary.
A UL listed conduit connector must be provided at each end
of the power supply cable (at the range and at the junction
box).
Wire sizes and connections must conform with the rating of
the range.
The wiring diagram is located on the back of the range or
inside the storage drawer in a clear plastic bag.
If connecting to a 4-wire system:
This range is manufactured with the ground connected to the
neutral by a link. The ground must be revised so the green
ground wire of the 4-wire power supply cord is connected to the
cabinet. See “Electrical Connection.”
Grounding through the neutral conductor is prohibited for new
branch-circuit installations (1996 NEC); mobile homes; and
recreational vehicles, or an area where local codes prohibit
grounding through the neutral conductor.
When a 4-wire receptacle of NEMA Type 14-50R is used, a
matching UL listed, 4-wire, 250-volt, 40- or 50-amp, range power
supply cord (pigtail) must be used. This cord contains 4 copper
conductors with ring terminals or open-end spade terminals with
upturned ends, terminating in a NEMA Type 14-50P plug on the
supply end.
The fourth (grounding) conductor must be identified by a green or
green/yellow cover and the neutral conductor by a white cover.
Cord should be Type SRD or SRDT with a UL listed strain relief
and be at least 4 ft (1.22 m) long.
The minimum conductor sized for the copper 4-wire power
cord are:
40-amp circuit
2 No.-8 conductors
1 No.-10 white neutral
1 No.-8 green grounding
If connecting to a 3-wire system:
Local codes may permit the use of a UL listed, 3-wire, 250-volt,
40- or 50-amp range power supply cord (pigtail). This cord
contains 3 copper conductors with ring terminals or open-end
spade terminals with upturned ends, terminating in a NEMA Type
10-50P plug on the supply end. Connectors on the appliance end
must be provided at the point the power supply cord enters the
appliance. This uses a 3-wire receptacle of NEMA Type 10-50R.
Range Rating* Specified Rating of
Power Supply Cord Kit
and Circuit Protection
120/240 Volts 120/208 Volts Amps
8.8 - 16.5 KW
16.6 - 22.5 KW
7.8 - 12.5 KW
12.6 - 18.5 KW
40 or 50**
50
4-wire receptacle (14-50R)
3-wire receptacle (10-50R)