Maytag W10252706B Installation Instructions Manual

Download Installation instructions manual of Maytag AER3311WA Cooktop, Ranges for Free or View it Online on All-Guides.com. This version of Maytag AER3311WA Manual compatible with such list of devices, as: AER3311WAW, MER7765WB - Ceramic Range, RF263LXTQ, WFE301LVB - 30 Inch Electric Range, WFE321LWB

Brand: Maytag

Category: Cooktop , Ranges

Type: Installation instructions manual

Model: Maytag AER3311WA , Maytag AER3311WAW , Maytag AER5522VA , Maytag AER5523XAB , Maytag AER5524XAD , Maytag AER5823XAS , Maytag AER5830VA , Maytag AER5830VAD , Maytag AER5830VAS , Maytag AER5844VA , Maytag AER5844VAS , Maytag AER6011VA , Maytag AER6011VAS , Maytag GFE461LVB - Ceramic Convection Range , Maytag GFE461LVQ - 30 Inch Electric Range , Maytag GFE461LVS - 30" Ing Electric Range , Maytag GFE461LVT - 30 Inch Electric Range , Maytag GFE471LVS , Maytag GFE471LVS - 30" Ing Electric Range , Maytag MER5605WB , Maytag MER7662WB , Maytag MER7662WQ - Ceramic Range , Maytag MER7662WS - Ceramic Range - Stainless , Maytag MER7662WW - 5.3 Cu Ft , Maytag MER7765WB - Ceramic Range , Maytag MER7765WS - Ceramic Range - Stainless , Maytag MER7765WW - 5.3 CF HIDDEN BAKE EVENAIR CONION DELAY KEEP WARM 2 6 , Maytag MER7775WB , Maytag MER7775WS , Maytag MER7775WW , Maytag RF110AXSQ , Maytag RF111PXSQ , Maytag RF114PXSB - 30" STANDARD CLEAN , Maytag RF114PXSQ - Electric , Maytag RF114PXST , Maytag RF212PXSQ , Maytag RF263LXTB - 30in Electric Range , Maytag RF263LXTQ , Maytag RF263LXTS - Electric , Maytag RF263LXTT , Maytag RF264LXSB - 30 Electric Range , Maytag RF264LXSQ , Maytag W10252706B , Maytag WFE115LXB , Maytag WFE115LXQ , Maytag WFE301LVB - 30 Inch Electric Range , Maytag WFE301LVQ , Maytag WFE321LWB , Maytag WFE321LWQ , Maytag WFE321LWS , Maytag WFE324LWB , Maytag WFE324LWQ , Maytag WFE361LVB - 30 Inch Electric Range , Maytag WFE361LVD - Universal 4.8 Cubic Foot Ele , Maytag WFE361LVQ - R 30 in. Ing Electric Range5 , Maytag WFE361LVT , Maytag WFE364LVB , Maytag WFE364LVS , Maytag WFE366LVB , Maytag WFE366LVQ - 30 Inch Electric Range , Maytag WFE366LVS - 30" - Electric Range , Maytag WFE366LVT - 30 IN SC CLEANTOP CERAN5 , Maytag WFE371LVB - 5.3 Cubic Foot Electric Range , Maytag WFE371LVQ , Maytag WFE374LVB , Maytag WFE374LVQ , Maytag WFE374LVS , Maytag WFE381LVB - 30 Inch Electric Range , Maytag WFE381LVQ - 30 Inch Electric Range , Maytag WFE381LVS - 30" Ing Electric Range

Pages: 16

Download Maytag AER3311WA Installation instructions manual

Maytag AER3311WA Installation instructions manual - Page 1
1
Maytag AER3311WA Installation instructions manual - Page 2
2
Maytag AER3311WA Installation instructions manual - Page 3
3
Maytag AER3311WA Installation instructions manual - Page 4
4
Maytag AER3311WA Installation instructions manual - Page 5
5
Maytag AER3311WA Installation instructions manual - Page 6
6
Maytag AER3311WA Installation instructions manual - Page 7
7
Maytag AER3311WA Installation instructions manual - Page 8
8
Maytag AER3311WA Installation instructions manual - Page 9
9
Maytag AER3311WA Installation instructions manual - Page 10
10
Maytag AER3311WA Installation instructions manual - Page 11
11
Maytag AER3311WA Installation instructions manual - Page 12
12
Maytag AER3311WA Installation instructions manual - Page 13
13
Maytag AER3311WA Installation instructions manual - Page 14
14
Maytag AER3311WA Installation instructions manual - Page 15
15
Maytag AER3311WA Installation instructions manual - Page 16
16
9
3. Feed the power supply cord through the strain relief on the
cord/conduit plate on bottom of range. Allow enough slack to
easily attach the wiring to the terminal block.
4. Use a Phillips screwdriver to connect the green ground wire
from the power supply cord to the range with the ground-link
screw and ground-link section. The ground wire must be
attached first.
5. Use ³⁄₈" nut driver to connect the neutral (white) wire to the
center terminal block post with one of the 10–32 hex nuts.
6. Connect line 2 (red) and line 1 (black) wires to the outer
terminal block posts with 10-32 hex nuts.
7. Securely tighten hex nuts.
NOTE: For power supply cord replacement, use only a power
cord rated at 250 volts minimum, 40 amps or 50 amps that is
marked for use with nominal 1³⁄₈" (3.5 cm) diameter
connection opening, with ring terminals and marked for use
with ranges.
8. Tighten strain relief screws.
9. Replace terminal block access cover.
3-wire connection: Power Supply Cord
Use this method only if local codes permit connecting chassis
ground conductor to neutral wire of power supply cord.
1. Feed the power supply cord through the strain relief on the
cord/conduit plate on bottom of range. Allow enough slack to
easily attach the wiring to the terminal block.
2. Use ³⁄" nut driver to connect the neutral (white) wire to the
center terminal block post with one of the 10–32 hex nuts.
3. Connect line 2 (red) and line 1 (black) wires to the outer
terminal block posts with 10-32 hex nuts.
4. Securely tighten hex nuts.
NOTE: For power supply cord replacement, use only a power
cord rated at 250 volts minimum, 40 amps or 50 amps that is
marked for use with nominal 1³⁄₈" (3.5 cm) diameter
connection opening, with ring terminals and marked for use
with ranges.
5. Tighten strain relief screws.
6. Replace terminal block access cover.
A. Terminal block
B. Ground-link screw
C. UL listed strain relief
D. Power supply cord wires
A. 10–32 hex nut
B. Ground-link screw
C. Line 2 (red)
D. Green ground wire
E. Neutral (center) wire
F. Line 1 (black)
A
B
D
C
A
B
C
F
D
E
A. Terminal block
B. Ground-link screw
C. UL listed strain relief
D. Power supply cord wires - large opening
A. 10–32 hex nut
B. Line 2 (red)
C. Ground-link screw
D. Neutral (white) wire
E. Line 1 (black)
A
B
D
C
A
B
C
D
E