Maytag MER7662WQ Installation Instructions Manual

Download Installation instructions manual of Maytag KERS202BSS Cooktop, Ranges for Free or View it Online on All-Guides.com. This version of Maytag KERS202BSS Manual compatible with such list of devices, as: MER8670AB, MER8670AS, MER8775AW, WFC340S0AW, WFE710H0AH

Maytag KERS202BSS Installation instructions manual - Page 1
1
Maytag KERS202BSS Installation instructions manual - Page 2
2
Maytag KERS202BSS Installation instructions manual - Page 3
3
Maytag KERS202BSS Installation instructions manual - Page 4
4
Maytag KERS202BSS Installation instructions manual - Page 5
5
Maytag KERS202BSS Installation instructions manual - Page 6
6
Maytag KERS202BSS Installation instructions manual - Page 7
7
Maytag KERS202BSS Installation instructions manual - Page 8
8
Maytag KERS202BSS Installation instructions manual - Page 9
9
Maytag KERS202BSS Installation instructions manual - Page 10
10
Maytag KERS202BSS Installation instructions manual - Page 11
11
Maytag KERS202BSS Installation instructions manual - Page 12
12
Maytag KERS202BSS Installation instructions manual - Page 13
13
Maytag KERS202BSS Installation instructions manual - Page 14
14
Maytag KERS202BSS Installation instructions manual - Page 15
15
Maytag KERS202BSS Installation instructions manual - Page 16
16
11
4-wire Connection: Direct Wire
Use this method for:
New branch-circuit installations (1996 NEC)
Mobile homes
Recreational vehicles
In an area where local codes prohibit grounding through the
neutral
1. Part of metal ground strap must be cut out and removed.
2. Use a Phillips screwdriver to remove the ground-link screw
from the back of the range. Save the ground-link screw and
the end of the ground link under the screw.
3. Pull the wires through the strain relief on bottom of range.
Allow enough slack to easily attach wiring to the terminal
block.
4. Attach terminal lugs to line 1 (black), neutral (white), and line 2
(red) wires. Loosen (do not remove) the setscrew on the front
of the terminal lug and insert exposed wire end through
bottom of terminal lugs. Securely tighten setscrew to torque
as shown in the following Bare Wire Torque Specifications
chart.
Bare Wire Torque Specifications
Attaching terminal lugs to the terminal block - 20 lbs-in. (2.3 N-m)
5. Use a hex or Phillips screwdriver to connect the bare (green)
ground wire to the range with the ground-link screw and
ground-link section. The ground wire must be attached first
and must not contact any other terminal.
6. Use ³⁄₈" nut driver to connect the neutral (white) wire to the
center terminal block post with one of the 10–32 hex nuts.
7. Connect line 2 (red) and line 1 (black) wires to the outer
terminal block posts with 10-32 hex nuts.
8. Securely tighten hex nuts.
9. Replace terminal block access cover.
A. Metal ground strap
B. Discard
C. Ground-link screw
A. Terminal block
B. Ground-link screw
C. Cord/conduit plate
D. Bare (green) ground wire
E. Line 2 (red) wire
F. Neutral (white) wire
G. Line 1 (black) wire
A
B
C
A
B
C
D
E
G
F
A. Terminal lug
B. Setscrew
C. Line 2 (red) wire
D. Neutral (white) wire
E. Line 1 (black) wire
Wire Awg Torque
8 gauge copper 25 lbs-in. (2.8 N-m)
6 gauge aluminum 35 lbs-in. (4.0 N-m)
A. 10–32 hex nut
B. Line 2 (red)
C. Bare (green) ground wire
D. Ground-link screw
E. Neutral (white) wire
F. Line 1 (black)
G. Terminal lug
A
B
C
DE
B
A
G
E
C
D
F