Maytag 3395316 Installation Instructions Manual

Download Installation instructions manual of Maytag 3395316 Dryer for Free or View it Online on All-Guides.com.

Brand: Maytag

Category: Dryer

Type: Installation instructions manual for Maytag 3395316

Pages: 12

Download Maytag 3395316 Installation instructions manual

Maytag 3395316 Installation instructions manual - Page 1
1
Maytag 3395316 Installation instructions manual - Page 2
2
Maytag 3395316 Installation instructions manual - Page 3
3
Maytag 3395316 Installation instructions manual - Page 4
4
Maytag 3395316 Installation instructions manual - Page 5
5
Maytag 3395316 Installation instructions manual - Page 6
6
Maytag 3395316 Installation instructions manual - Page 7
7
Maytag 3395316 Installation instructions manual - Page 8
8
Maytag 3395316 Installation instructions manual - Page 9
9
Maytag 3395316 Installation instructions manual - Page 10
10
Maytag 3395316 Installation instructions manual - Page 11
11
Maytag 3395316 Installation instructions manual - Page 12
12
Recessed area
and closet
installations
Fire/Health Hazard
Exhaust dryers to the outslde to
prevent exposure to substances In
the gas fuels and combustion
byproducts which may be harmful
to your health.
Failure to do so may result In a flre
or health hazard.
Thls appliance may be Installed In a
recessed area.
The installation spacing is the
minimum allowable. Additional
spacing should be considered for
ease of installation, servicing and
compliance with local codes and
ordinances.
If closet door is installed, the minimum
unobstructed air openings in the top
and bottom are required. Door
must
have two centered openings as
illustrated. Both openings must
provide a minimum of 72 square
inches of unobstructed airflow as
shown. Louvered doors with
equivalent air openings are
acceptable.
Do Not block airflow at the bottom
front of the dryer with laundry or rug.
Airflow from the bottom of the dryer is
needed for operating efficiency.
AddItIonal
clearances
maybe
required for
wall, door
and floor
mokiln
If
T
extema
exhousf
elbow Is
Used.
o”-B
P-
O”-D
Recessed front view
Closet view
Side view
0” -D
Additional
clearances
may be
rx:f
door aid
iloor
moldings
if external
exhaust
elbow is
used.
r
Additional
may be required.
Front view
Closet
0
door Am
I
3
L
3”
Opening is minimum for closet door.
Louvered door with equivalent air openings
is acceptable.
Companion appliance spacing
should be considered.
FOR CLOSET INSTALLATIONS, TO
PREVENT LARGE AMOUNTS OF LINT
AND MOISTURE FROM
ACCUMULATING, TO MAINTAIN
DRYING EFFICIENCY, AND TO PREVENT
EXPOSURE TO POSSIBLE HEALTH
HAZARDS, DRYERS MUST BE
EXHAUSTED OlKDOORS.
No other fuel-burnlng appliance may
be Installed In the same closet.
Page 9