Maytag W10096988A Installation Instructions Manual

Download Installation instructions manual of Maytag Cabrio,- WED5500X Dryer for Free or View it Online on All-Guides.com. This version of Maytag Cabrio,- WED5500X Manual compatible with such list of devices, as: W10306460A-SP, WED5500XL, WED5600XW, WED5700XL, WED5700XW

Maytag Cabrio,- WED5500X Installation instructions manual - Page 1
1
Maytag Cabrio,- WED5500X Installation instructions manual - Page 2
2
Maytag Cabrio,- WED5500X Installation instructions manual - Page 3
3
Maytag Cabrio,- WED5500X Installation instructions manual - Page 4
4
Maytag Cabrio,- WED5500X Installation instructions manual - Page 5
5
Maytag Cabrio,- WED5500X Installation instructions manual - Page 6
6
Maytag Cabrio,- WED5500X Installation instructions manual - Page 7
7
Maytag Cabrio,- WED5500X Installation instructions manual - Page 8
8
Maytag Cabrio,- WED5500X Installation instructions manual - Page 9
9
Maytag Cabrio,- WED5500X Installation instructions manual - Page 10
10
Maytag Cabrio,- WED5500X Installation instructions manual - Page 11
11
Maytag Cabrio,- WED5500X Installation instructions manual - Page 12
12
Maytag Cabrio,- WED5500X Installation instructions manual - Page 13
13
Maytag Cabrio,- WED5500X Installation instructions manual - Page 14
14
Maytag Cabrio,- WED5500X Installation instructions manual - Page 15
15
Maytag Cabrio,- WED5500X Installation instructions manual - Page 16
16
Maytag Cabrio,- WED5500X Installation instructions manual - Page 17
17
Maytag Cabrio,- WED5500X Installation instructions manual - Page 18
18
Maytag Cabrio,- WED5500X Installation instructions manual - Page 19
19
Maytag Cabrio,- WED5500X Installation instructions manual - Page 20
20
11
3-wire Direct Wire Connection
Use where local codes permit connecting cabinet-ground
conductor to neutral wire.
B
5. Remove center screw
Remove center, silver-colored terminal block screw (B).
7. Connect ground wire
A
F
Connect ground wire (green or bare) (F) of direct wire cable
to external ground conductor screw (A). Tighten screw.
Place hooked ends of remaining direct wire cable wires
under outer terminal block screws (hooks facing right).
Squeeze hooked ends together and tighten screws. Finally,
reinsert tab of terminal block cover into slot of dryer rear
panel. Secure cover with hold-down screw. Now, go to
Venting Requirements.
8. Connect remaining wires
B
E
C
6. Connect neutral ground wire
and neutral wire
Connect neutral ground wire (E) and place hooked end (hook
facing right) of neutral wire (white or center wire) (C) of direct
wire cable under center screw of terminal block (B). Squeeze
hooked ends together and tighten screw.
Direct wire cable must have 5 ft. (1.52 m) of extra length so
dryer may be moved if needed.
Strip 3
1
/
2
" (89 mm) of outer covering from end of cable. Strip
insulation back 1" (25 mm). If using 3-wire cable with ground
wire, cut bare wire even with outer covering. Shape wire ends
into hooks.
1"
(25 mm)
3½"
(89 mm)
3. Prepare your 3-wire cable for
direct connection
To connect wires to terminal block, place hooked end of wire
under terminal block screw, facing to the right, squeeze
hooked end together and tighten screw.
4. Connect wires to terminal block