Maytag EPIC Z MGD9800TK0 Use & Care Manual
Download Use & care manual of Maytag EPIC Z MGD9800TB0 Dryer, Other for Free or View it Online on All-Guides.com.
Brand: Maytag
Type: Use & care manual
Model: Maytag EPIC Z MGD9800TB0 , Maytag EPIC Z MGD9800TK0 , Maytag EPIC Z MGD9800TQ0
Pages: 84
Gas supply connection requirements
• Use an elbow and a %" flare x %" NPT adapter fitting between the flexible gas connector
and the dryer gas pipe, as needed to avoid kinking.
• Use only pipe-joint compound. Do not use TEFLON _* tape.
• This dryer must be connected to the gas supply line with a listed flexible gas connector
that complies with the standard for connectors for gas appliances, ANSI Z21.24 or CSA
6.10.
Burner input requirements
Elevations above 10,000 ft (3,048 m):
• When installed above I0,000 ft (3,048 m) a 4% reduction of the burner Btu rating shown
on the model/serial number plate is required for each ,000 ft (7_;05m) increase in
elevation.
Gas supply pressure testing
• The dryer must be disconnected from the gas supply piping system during pressure testing
at pressures greater than V2psi.
Dryer gas pipe
• The gas pipe that comes out through the rear of your dryer has a 3/8"male pipe thread.
A. ½" NPT gas supply line
B. _" NPT dryer pipe
*NOTE: If the dryer is mounted on a pedestal, the gas pipe height must be an additional 10"
(25.4 cm) or 1.>.._ (39.4 cm) from the floor, depending on the pedestal model. For a garage
installation, the gas pipe height must be an additional 18" (46 cm) from the floor.
¢)
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death
or fire.
WARNING: Io reduce the risk of fire, this dryer MUS-] BE EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
[he dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling or a
concealed space of a building.
If using an existing vent system
• Clean lint from the entire length of the system and make sure exhaust hood is not plugged
with lint.
• Replace any plastic or metal foil vent with rigid or flexible heavy metal vent.
• Review Vent system chart. Modify existing vent system if necessary to achieve the best
drying performance.
If this is a new vent system
Vent material
• Use a heavy metal vent. Do not use plastic or metal foil vent.
• 4" (10.2 cm) heavy metal exhaust vent and clamps must be used.
4" ( 10.2 cm) heavy metal _'xhaust v_'nt
Vent products can be purchased from your dealer or by calling Maytag Services. For more
information, see the "Assistance or Service" section.
10