Maytag POF1HD140AVFA Installation, Operation And Maintenance Manual

Download Installation, operation and maintenance manual of Maytag POF1HD091AVFA Furnace for Free or View it Online on All-Guides.com.

Brand: Maytag

Category: Furnace

Type: Installation, operation and maintenance manual

Model: Maytag POF1HD091AVFA , Maytag POF1HD140AVFA

Pages: 36

Download Maytag POF1HD091AVFA Installation, operation and maintenance manual

Maytag POF1HD091AVFA Installation, operation and maintenance manual - Page 1
1
Maytag POF1HD091AVFA Installation, operation and maintenance manual - Page 2
2
Maytag POF1HD091AVFA Installation, operation and maintenance manual - Page 3
3
Maytag POF1HD091AVFA Installation, operation and maintenance manual - Page 4
4
Maytag POF1HD091AVFA Installation, operation and maintenance manual - Page 5
5
Maytag POF1HD091AVFA Installation, operation and maintenance manual - Page 6
6
Maytag POF1HD091AVFA Installation, operation and maintenance manual - Page 7
7
Maytag POF1HD091AVFA Installation, operation and maintenance manual - Page 8
8
Maytag POF1HD091AVFA Installation, operation and maintenance manual - Page 9
9
Maytag POF1HD091AVFA Installation, operation and maintenance manual - Page 10
10
Maytag POF1HD091AVFA Installation, operation and maintenance manual - Page 11
11
Maytag POF1HD091AVFA Installation, operation and maintenance manual - Page 12
12
Maytag POF1HD091AVFA Installation, operation and maintenance manual - Page 13
13
Maytag POF1HD091AVFA Installation, operation and maintenance manual - Page 14
14
Maytag POF1HD091AVFA Installation, operation and maintenance manual - Page 15
15
Maytag POF1HD091AVFA Installation, operation and maintenance manual - Page 16
16
Maytag POF1HD091AVFA Installation, operation and maintenance manual - Page 17
17
Maytag POF1HD091AVFA Installation, operation and maintenance manual - Page 18
18
Maytag POF1HD091AVFA Installation, operation and maintenance manual - Page 19
19
Maytag POF1HD091AVFA Installation, operation and maintenance manual - Page 20
20
Maytag POF1HD091AVFA Installation, operation and maintenance manual - Page 21
21
Maytag POF1HD091AVFA Installation, operation and maintenance manual - Page 22
22
Maytag POF1HD091AVFA Installation, operation and maintenance manual - Page 23
23
Maytag POF1HD091AVFA Installation, operation and maintenance manual - Page 24
24
Maytag POF1HD091AVFA Installation, operation and maintenance manual - Page 25
25
Maytag POF1HD091AVFA Installation, operation and maintenance manual - Page 26
26
Maytag POF1HD091AVFA Installation, operation and maintenance manual - Page 27
27
Maytag POF1HD091AVFA Installation, operation and maintenance manual - Page 28
28
Maytag POF1HD091AVFA Installation, operation and maintenance manual - Page 29
29
Maytag POF1HD091AVFA Installation, operation and maintenance manual - Page 30
30
Maytag POF1HD091AVFA Installation, operation and maintenance manual - Page 31
31
Maytag POF1HD091AVFA Installation, operation and maintenance manual - Page 32
32
Maytag POF1HD091AVFA Installation, operation and maintenance manual - Page 33
33
Maytag POF1HD091AVFA Installation, operation and maintenance manual - Page 34
34
Maytag POF1HD091AVFA Installation, operation and maintenance manual - Page 35
35
Maytag POF1HD091AVFA Installation, operation and maintenance manual - Page 36
36
28
Table C-4: System and General Troubleshooting continued
Problem Possible Cause Remedy
Airflow blocked or dirty air
filter.
Clean or replace air filter.
Supply air temperature
too hot.
Insufficient airflow.
Check all dampers. Open closed dampers including registers in
unused rooms. Check system temperature rise. If temperature
rise is too high, speed up blower fan.
Excess airflow.
Check system temperature rise. Slow down blower fan if
necessary.
Supply air temperature
too cool.
Excessive duct losses.
Check supply air ductwork. Seal leaky joints and seams.
Insulate ductwork if necessary.
Fan control "fan on" setting too
low.
Increase "fan on” dipswitch settings on EFT if control has this
option.). Register air deflectors may help.
Supply air temperature
too cool during first
moments of furnace
cycle.
Excessive duct losses.
Check supply air ductwork. Seal leaky joints and seams.
Insulate ductwork if necessary.
FINAL CHECK OUT 3. Where the oil shut-off valve from the oil storage
tank is located.
ENSURE THAT ALL SAFETY DEVICES AND
ELECTRICAL COMPONENTS HAVE BEEN
SET FOR NORMAL OPERATION. ENSURE
THAT ALL ELECTRICAL CONNECTIONS
ARE TIGHT AND THAT THE WIRING IS
SECURE.
4.
How to operate the thermostat, and other
related accessories.
5. How to operate the manual reset button on the
primary control, and especially when not to push the
reset button.
6. How and where to visually inspect the venting
system for leaks or other problems.
IMPORTANT:
7.
How to inspect, clean and replace the air filter,
and other homeowner maintenance procedures.
Please ensure that the homeowner is informed and
understands:
8. Who to call for emergency service and routine
annual service.
1. Where the circuit breaker or fuse is located in
the main electrical panel.
9. The terms and conditions of the manufacturer's
warranty and the contractor's warranty.
2. Where the furnace switch is located, and the
switch "on" and "off" positions if not obvious.