BEA 80.0249.00 Installation manual - Page 1
1
SIZE:
DRAWN BY:
TITLE: MC-LINX2 WITH 3 or 4
DOOR INTERLOCK
A
NOTES:
1.) Door Position Switch (DPS) shall close when it's respective door closes.
2.) If only a 3 door interlock is desired ensure to insert a jumper into input 4 on
MCLinx2 (#2)
100 ENTERPRISE DRIVE
PITTSBURGH, PA 15275
PHONE: (412) 249-4100
FAX: (412) 249-4101
EMAIL: www.beasensors.com
REV BY:
JED JED
80.0249.00
SCALE: DATE:
NONE 18 DEC., 2006
PART NO:
SHEET
1 OF 1
MC-LINX2
# 2
1234WET
OUTPUT
AB
POWER
OUTPUT OPTION SETUP
INPUT
5
12 to 24 VAC/VDC
+/- 10%
Input 3 is the door position switch
for Input 1 (Door 3).Input 4 is the door
position switch for input 2 (Door 4) if used.
Switch is closed when door is closed.
0
RELAY COIL
PUSH
PLATE
1
PUSH
PLATE
2
MC-LINX2
# 1
1234WET
OUTPUT
AB
POWER
OUTPUT OPTION SETUP
INPUT
5
12 to 24 VAC/VDC
+/- 10%
Input 1 and Input 2
are activation inputs
for Door 1 and Door 2
respectively
Inputs 3 and 4 are for the door position
switch for Input 1 (Door 1) and
Input 2 (Door 2) respectively.
Switch is closed when door is closed.
0
Output A directly to Activation Circuit of
Door Control #1. Output B directly to
Activation Circuit of Door Control #2.
DOOR 3
DPS
DOOR 2
DPS
PUSH
PLATE
3
13 14
Omron Part #
MY4INDC24 or
MY4INAC24
9
12
1
4
5
8
11
3
7
5
10
2
6
DOOR 1
DPS
Socket #
PTF14AE
IF AFTER TROUBLESHOOTING A PROBLEM, A SATISFACTORY SOLUTION CANNOT BE ACHIEVED, PLEASE CALL B.E.A., INC.
FOR FURTHER ASSISTANCE DURING EASTERN STANDARD TIME AT 1-800-523-2462 FROM 8AM - 5PM. FOR AFTER-HOURS,
CALL EAST COAST: 1-866-836-1863 OR 1-800-407-4545 / MID-WEST: 1-888-308-8843 / WEST COAST: 1-888-419-2564. DO NOT
LEAVE ANY PROBLEM UNRESOLVED. IF YOU MUST WAIT FOR THE FOLLOWING WORKDAY TO CALL B.E.A., LEAVE THE
DOOR INOPERABLE UNTIL SATISFACTORY REPAIRS CAN BE MADE. NEVER SACRIFICE THE SAFE OPERATION OF THE
AUTOMATIC DOOR OR GATE FOR AN INCOMPLETE SOLUTION.WEB: WWW.BEASENSORS.COM
DOOR 4
DPS
PUSH
PLATE
4
Output A directly to Activation Circuit of
Door Control #3. Output B directly to
Activation Circuit of Door Control #4 if used.
Input 1 and Input 2
are activation inputs
for Door 3 and Door 4
respectively
(SEE NOTE #2)
(SEE NOTE #1)