Protection for small electronic equipment
ES550C / ES800C / ES1000C / ES1500C
Features
The ESC series offer the highest power capacity and the best equipment protection around. Not only do they protect
against blackouts, sags and surges, but with the added feature of AVR (Automatic Voltage Regulator), these UPS
products ensure that only clean and safe currents reach your equipment.
What is AVR?
AVR is a feature that corrects under and over voltages without draining the battery, thus providing extended battery life
and, most important, allowing the UPS to provide high quality power during unacceptable voltage fluctuations.
ES550C / ES800C / ES1000C / ES1000C-RM / ES1500C /
ES1500C-RM
* Easy battery replacement procedure
* 1050 Joules surge energy rating
* 4 hours battery recharge time
* Smart power management software
* AVR (automatic voltage regulator)
* Up to 8 battery backup outlets
* RJ11/RJ45 protection
1PC+1LCD 21 mins
1PC+1LCD 33 mins
1PC+1LCD 40 mins
1PC+1LCD 45 mins
ES550C
ES800C
ES1000C
ES1500C
Backup Time (Typical)
* ES1500C
Front Panel
ES550C / ES800C
ES1000C / 1500C
Battery
Fault
Battery
Mode
AC
Mode
ON/OFF
TEST/SILENCE
A
B C D
A) Battery Fault
B) Battery Mode
C) AC Mode
D) On / Off, Test / Silence
Battery
Fault
Buck
Battery
Mode
AC Mode
C D E F
Boost
ON/OFF
TEST/SILENCE
BA
A) Battery Fault
B) Buck
C) Battery Mode
D) Boost
E) AC Mode
F) On / Off, Test / Silence
Rear Panel
100V
110V
120V
220V
230V
240V
100V
110V
120V
220V
230V
240V
ES550C / ES800C
ES1000C / ES1500C
Communication
Port
Battery Backup
Outlets
Convenience
Outlets
Surge Protected
Outlets
Input
Output
Breaker
Input
11.
Specifications
550VA / 330W 800VA / 480W 1000VA / 700W 1400VA / 980W
8 Battery backup (US)
8 Battery backup (IEC)
14.9 x 5.5 x 7.9 / 19.2 x 10.6 x 12.8
378 x 140 x 201 / 487 x 270 x 326
Model Name
Topology
On-battery Output Waveform
INPUT
Maximum Capacity
Nominal Input Voltage
Nominal Input Frequency
Input Voltage Range
Input Short Protection
OUTPUT
Nominal Output Voltage
Output Voltage Regulation
Transfer Time
Number of Outlets
PROTECTION
Automatic Voltage Regulation
(AVR)
Data Line Surge Protection
Surge Energy Rating
Normal Mode Noise Suppression
BATTERY
User Replaceable Battery
Recharge Time to 90%
Audible Alarms
COMMUNICATION INTERFACE
Communication Port*
ENVIRONMENTAL
Operation Temperature
Storage Temperature
Audible Noise
PHYSICAL
Dimensions
(Physical / Packing)
(L x W x H)
Weight
(Net / Gross)
CONFORMANCE
14.1 / 16.1
6.4 / 7.3
ES550C ES800C ES1000C ES1500C
3 UPS outlets + 3 Surge protected outlets (US)
3 UPS outlets + 2 Surge protected outlets (IEC)
12V/7.2AH x 1 12V/34W x 1 12V/7.2AH x 2 12V/34W x 2
RS232
12.7 x 4 x 6.5 / 16.1 x 7.7 x 10.6
322 x 102 x 165 / 410 x 195 x 268
(in)
(mm)
31.1 / 33.3
14.1 / 15.7
35.7 / 39.2
16.2 / 17.8
Specifications are subject to change without notice.
* You can purchase RS232 to USB cable.
** See VS1000C on page 6
(lbs)
(kg)
15.4 / 17.4
7 / 7.9
Approvals
Circuit Breaker
< 4 Hours
Battery mode / UPS fault / Overload
0°~40°C / 32°~104°F
-20°~60°C / -4°~140°F
< 40 dBA
100 / 110 / 120Vac or 220 / 230 / 240Vac**
50Hz / 60Hz Auto Sensing
Rated Voltage +/- 25%
Circuit Breaker (US), Fuse (IEC)
100 / 110 / 120Vac or 220 / 230 / 240Vac**
Rated Voltage +/- 5% (on battery)
4 ms (typical)
Yes
RJ11 / RJ45
1050 Joules
Full time EMI/RFI filtering
BSMI ; CE ; UL / cUL ; C-Tick, A-Tick ; GOST-R
Line-interactive
Simulated Sine Wave
Win
windows
95/98
ME/NT
IBM
IBM OS/2
IBM AIX
SUN Solaris
HP-UX
SGI Irix
Novell Netware
Linux
FreeBSD
windows
2000 / XP
2003 / Vista
Simulated
Sine Wave
For personal computers and work stations
Communication
Port
Data Line
Protection
Data Line
Protection