Davey XJ Ultra Installation and operating instructions - Page 1
1
Davey XJ Ultra Installation and operating instructions - Page 2
2
Installation and
Operating Instructions
for Dynajet
®
XJ Ultra/XJ70P/XJ90P
Pressure Pumps &
XJ50/XJ70/XJ90
Electric Pumps
Trouble Shooting Check List
a) MOTOR RUNS WHEN SWITCHED ON BUT DOES NOT PUMP.
1. Suctionlineandpumpbodynotlledwithwater.
2. Airleaksinsuctionlinesorsuctionpipenotunderwater.
3. Airtrappedinsuctionlines(alsopossiblewithoodedsuctiondueto
unevenriseinpiping;eliminatehumpsandhollows).
4. Nowateratsourceorwaterleveltoolow.
5. Valveonsuctionlinesclosed.
b) PUMP SWITCHES ON AND OFF FREQUENTLY (CYCLING) -
Pressure
Pumps Only
1. Checkthattankairpressureiscorrect-seeabove.
2. Leakingtaps,oatvalvesetc.checkplumbing.
3. Leakingcheckvalve/footvalve.
c) MOTOR DOESN’T START WHEN SWITCHED ON.
1. Powernotconnected.
2. Supplyvoltagetoolow.
3. “Overtemperature”cut-outtripped.*
4. Motornotfreetoturneg.ajammedimpeller.
5. Internalmotorfault.
Maintenance
Theonlyregularattentionyournewpressuresystemrequiresistocheckthe
pressuretank’sairchargeevery6months.Thiscanbecheckedattheair
valvewithatyregauge.Donotchargetanktoahigherpressurethan168kPa
(XJUltra)or196kPa(XJ70P&XJ90P).
Tocheckairpressureintank:
1. Switchoffpump.
2. Openoutletnearesttopumptorelease
waterpressure.
3. Removeairvalvecapfromtopof
Supercelltankandchargetankto168kPa
(XJUltra)or196kPa(XJ70P&XJ90P)
usingairpumpandcheckwithtyre
gauge.
4. Switchon.
5. Closeoutlet.
After Sales Service
ForprofessionalaftersalesserviceorrepaircontactyourDaveyDealer.For
assistanceinlocatingyournearestdealercontacttheDaveyCustomerServiceCentre
on1300367866
P/N 48661-6 Supersedes P/N 48661-5
Please pass these instructions on to the operator of this equipment.
Priming and Operation
1.Fillpumpandsuctionline(on
oodedsuction,simplyopengate
valvetopump).Whenfull,t
Supercell
PressureTank
orPriming
Plugas
applicable.
2.Ensureoutletnearesttopumpis
open.
3.Ensureallvalvesinsuctionlineare
openandswitchon.
4.Primeshouldestablishalmost
immediatelyandastrongow
ofwatershouldbe
evidentfromthe
outlet.Allowwaterto
owfor10-20seconds
toexpelairthenclose
outlet.
5.AutomaticPressure
Pumpswillshutdownautomatically
withinseveralseconds.Manual
systemsmustbeswitchedoffat
thepowerpoint.
6.Ifnoowisevidentfromtap,
switchoffatpowerpointandrepeat
fromstep1ensuringthereisan
adequatesupplyofwateravailable
tothepump.
DAVEY WATER PRODUCTS GUARANTEE FOR AUSTRALIA & NEW ZEALAND
This Davey product is guaranteed to be free of material or manufacturing defects at the time of original purchase. Should any part fail
as a result of such defects within two years of original purchase, the product will be repaired free of charge.
TERMS AND CONDITIONS
1. This guarantee applies to all states and territories of Australia and New Zealand only and is subject to the provisions of the Trade
Practices Act (Aust.), the Goods and Consumer Protection Legislation of the various Australian states and the Consumers Guarantee
Act 1993 (NZ) as applicable.
2. The guarantee period commences on the date of original purchase of the equipment. Evidence of this date of original purchase
must be provided when claiming repairs under guarantee. It is recommended you retain all receipts in a safe place.
3. This guarantee covers parts and workshop labour only. Goods should be forwarded, with proof of date of original purchase, to an
Authorised Davey Service Centre freight paid.
4. This guarantee is subject to due compliance by the original purchaser with all directions and conditions set out in the Installation
and Operating Instructions. Failure to comply with these instructions, damage or breakdown caused by fair wear and tear,
negligence, misuse, incorrect installation, chemical or additives in the water, inadequate protection against freezing, rain or
other adverse weather conditions, corrosive or abrasive water, lightning or high voltage spikes or through unauthorised persons
attempting repairs are not covered under guarantee. The product must only be connected to the voltage shown on the
nameplate.
5. Without limiting the original purchaser’s entitlements under the Trade Practices Act (Aust.), the Goods & Consumer Protection
Legislation of the various Australian states, or the Consumers Guarantee Act 1993 (NZ), Davey shall not be liable for any loss of
profits or any consequential, indirect or special loss, damage or injury of any kind whatsoever arising directly or indirectly from the
product or any defect.
6. Where the Trade Practices Act (Aust.), the Goods and Consumer Protection Legislation of the various Australian states and the
Consumers Guarantee Act 1993 (NZ) does not apply, Davey shall not be liable for any loss of profits or any consequential, indirect
or special loss, damage or injury of any kind whatsoever suffered by the purchaser arising directly or indirectly from the product or
any defect and the purchaser shall indemnify Davey against any claim by any other person whatsoever in respect of any such loss,
damage or injury.
7. Nothing in this guarantee is intended to have the effect of contracting out of the provisions of the Trade Practices Act (Aust.),
the Goods and Consumer Protection Legislation of the various Australian states and Consumers Guarantee Act 1993 (NZ) except
to the extent permitted by the various Acts and this guarantee is to be modified to the extent necessary to give effect to that
intention.
8. Davey may be collecting personal information from you in order to provide you with a service. Davey Water Products Pty Ltd
promises only to use this information in accordance with the Provisions of the Privacy Act 1988 (Cth) and the Privacy Policy of
Davey Water Products Pty Ltd which is available at davey.com.au.
® Davey and Dynajet are registered trademarks of Davey Water Products Pty Ltd. © Davey Water Products Pty Ltd 2000
Never operate your Davey Dynajet
®
pump for more than a few
seconds without discharge ow.
*NOTE: For protection, the Davey pump motor is tted with an
automatic “over temperature” cut-out. Constant tripping of this
overload device indicates a problem eg. low voltage at pump,
excessive temperature (above 45
o
C) in pump enclosure.
Care should also be taken when servicing or disassembling pump to
avoid possible injury from hot pressurised water. Unplug pump,
relieve pressure by opening a tap on the discharge side of the pump
and allow any hot water in the pump to cool before attempting to
dismantle.
During servicing, use only approved, non-petrochemical based oring
and gasket lubrication. If unsure, consult your Davey Dealer for advice.
WARNING: When servicing or attending pump, always ensure power
is switched off and lead unplugged. Electrical connections should be
serviced only by qualied persons.
WARNING: Do not use hydrocarbon based or hydrocarbon propelled
sprays around the electrical components of this pump.
NOTE: Prior to installation remove the red
transport plugs from the suction and/or discharge.
Davey Water Products Pty Ltd
Member of the GUD Group
ABN
18 066 327 517
Head Office and Manufacturing
6 Lakeview Drive,
Scoresby, Australia 3179
Ph: +61 3 9730 9222
Fax: +61 3 9753 4100
Website: davey.com.au
Customer Service Centre
Ph: 1300 367 866
Fax: 1300 369 119
E-mail: sales@davey.com.au
Interstate Offices
Sydney • Brisbane • Adelaide
Perth • Townsville
International
6 Lakeview Drive,
Scoresby, Australia 3179
Ph: +61 3 9730 9222
Fax: +61 3 9753 4248
AH: +61 3 9730 9121
E-mail: export@davey.com.au
Germany
Kantstrasse 47,
04275 Leipzig
Ph: +49 341 301 0412
Fax: +49 341 301 0413
New Zealand
2 Rothwell Avenue,
North Harbour, Auckland 1330
Ph: +64 9 914 3680
Fax: +64 9 914 3685
Website: daveynz.co.nz
U.S.A. - Davey Pumps Inc.
1005 N. Commons Drive
Aurora, Illinois 60504
Ph: +1 630 898 6976
Fax: +1 630 851 7744
Website: daveyusa.com
In accordance with AS 3350.2.41 we are obliged to inform you that this
pump is not to be used by children or inrm persons and must not be
used as a toy by children.