NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
HEARTH PRODUCTS
KITS AND ACCESSORIES
INSTALLATION INSTRUCTIONS FOR BLACK - SV4.5CTS-B (CAT. NO. H4716) & SV8CTS-B (CAT. NO. H6179)
AND TERRA COTTA - SV4.5CTS-TC (CAT. NO. H4717) & SV8CTS-TC (CAT. NO. H6180) TERMINATIONS
DIRECT VENT
CHASE TOP SQUARE
VERTICAL TERMINATIONS
750,207M
REV. A 07/2007
GENERAL INFORMATION
The SV4.5CTS and SV8CTS series terminations are designed to be
installed on top of locally fabricated chimney enclosure, referred to
herein as a chase. The terminations are designed to be used with tested
and listed Direct Vent pipe systems and manufactured appliances listed
for use with this product. The SV4.5CTS and SV8CTS terminations are
additionally designed and painted to be suitable for use by itself without
surround, providing a beautiful top to a standard chase.
WARNINGS
This termination is intended to be installed in accordance with the
installation guidelines of the pipe system and appliance it is joined to.
Failure to install this product within those guidelines as well as these
installation instructions can result in damage of property, bodily injury,
or death. The installation must conform with local codes or, with the
national fuel gas code, or ANSI Z223.1.
It is highly recommended that this product be installed by a qualified
technician. It is highly recommended that the technician be NFI certified
for gas appliance installations.
APPROVALS AND LISTINGS
The SV4.5CTS and SV8CTS series terminations are tested as a integral
component of the Direct Vent pipe system and may be used with any
manufactured fireplace listed for use with these components. These
terminations are listed for this application by Omni-Test Laboratories.
FOR YOUR SAFETY
When working on ladders, roofs, scaffolding, or any high surface, take
precautions to protect against accidents. Properly secure ladders, wear
safety harnesses and verify all operations are done to OSHA standards.
Also be aware of and avoid any and all electrical wires in or near your
working area.
When working with and around sheet metal, be aware of material edges.
Always wear gloves, safety glass and any other needed protective gear
when working with sheet metal.
Take appropriate precautions when operating power equipment.
KIT CONTENTS
1 - Termination
1 - Bag with fifteen (15) stainless steel screws
1 - Instruction Sheet
SV4.5CTS
Or SV8CTS
Termination
Chase Flashing
(Field Fabricated)
Pipe
Section