Carrier Infinity Control Installation Instructions Manual

Download Installation instructions manual of Carrier Infinity Control Home Household Appliance, Humidifier for Free or View it Online on All-Guides.com.

Carrier Infinity Control Home Installation instructions manual - Page 1
1
Carrier Infinity Control Home Installation instructions manual - Page 2
2
Carrier Infinity Control Home Installation instructions manual - Page 3
3
Carrier Infinity Control Home Installation instructions manual - Page 4
4
Carrier Infinity Control Home Installation instructions manual - Page 5
5
Carrier Infinity Control Home Installation instructions manual - Page 6
6
Carrier Infinity Control Home Installation instructions manual - Page 7
7
Carrier Infinity Control Home Installation instructions manual - Page 8
8
Carrier Infinity Control Home Installation instructions manual - Page 9
9
Carrier Infinity Control Home Installation instructions manual - Page 10
10
Carrier Infinity Control Home Installation instructions manual - Page 11
11
Carrier Infinity Control Home Installation instructions manual - Page 12
12
Carrier Infinity Control Home Installation instructions manual - Page 13
13
Carrier Infinity Control Home Installation instructions manual - Page 14
14
Carrier Infinity Control Home Installation instructions manual - Page 15
15
Carrier Infinity Control Home Installation instructions manual - Page 16
16
SYSTXCCUID01-- B
Infinityt Control
Installation Instructions
HOLD
COOL
HEAT
OFF
A03149
Fig. 1 -- Infinityt Control
NOTE: Read the entire instruction manual before starting the
installation.
TABLE OF CONTENTS
PAGE
SAFETY CONSIDERATIONS 1.........................
INTRODUCTION 1...................................
INSTALLATION AND START--UP OVERVIEW 1..........
INSTALLATION 2....................................
INSTALLING INFINITY CONTROL 4....................
INITIAL POWER--UP 5................................
QUICK START 7.....................................
INSTALL / SERVICE MENUS 7.........................
EQUIPMENT SUMMARY MENU 8......................
INSTALL MENU 8....................................
SETUP MENU 8......................................
CHECKOUT MENUS 12...............................
SERVICE MENUS 12..................................
OPERATIONAL INFORMATION 14.....................
TROUBLESHOOTING 15..............................
SYSTEM MALFUNCTION SCREEN 16..................
SAFETY CONSIDERATIONS
Read and follow manufacturer instructions carefully. Follow all
local electrical codes during installation. All wiring must conform
to local and national electrical codes. Improper wiring or
installation may damage the Infinity System.
Recognize safety information. This is the safety--alert symbol
.
When you see this symbol on the equipment and in the instruction
manual, be alert to the potential for personal injury. Understand the
signal words DANGER, WARNING, and CAUTION.
These words are used with the safety--alert symbo l. DANGER
identifies the most serious hazards, which will result in severe
personal injury or death. WARNING signifies a hazard, which
could result in personal injury or death. CAUTION is used to
identify unsafe practices, which may result in minor personal
injury or product and property damage. NOTE is used to highlight
suggestions which will result in enhanced installation, reliability, or
operation.
INTRODUCTION
The Infinity System consists of several intelligent communicating
components which includes the Infinity Control (or User
Interface), variable speed furnace or FE fan coil, 2--stage AC or HP
and Infinity Packaged Products, which continually communicate
with each other via a four--wire connection called the ABCD bus.
Commands, operating conditions, and other data are passed
continually between components over the ABCD bus. The result is
a new level of comfort, versatility, and simplicity.
All Infinity furnaces or fan coils are variable--speed and multi stage
for maximum flexibility, efficiency , and comfort. They support
controlled ventilation, humidification, dehumidification, and air
quality control. Either an Infinity (communicating), or a standard
24VAC controlled outdoor unit may be used.
When using conventional outdoor units, the Infinity furnace or fan
coil provides the 24 volt signals needed to control them. Also, the
Infinity Network Interface Module (P/N SYSTXCCNIM01) allows
connection of a Carrier HRV or ERV without the need for a
separate wall control.
All system components are controlled through the wall mounted
Infinity Control, which replaces the c onventional thermostat and
provides the homeowner with a single wall control for all features
of the system.
INSTALLATION AND START--UP
OVER VIEW
This instruction covers installation of the Infinity Control only.
Physical installation instructions for the indoor and outdoor
equipment, and accessories are provided with each unit.
Setup, commissioning, operation, and troubleshooting of the
Infinity System are covered only in this installation instruction. It is
the guide to connecting the system components and
commissioning the system once all physical components are
installed. Special screen prompts and start--up capabilities are
provided in the Infinity System to simplify and automate the initial
commissioning of the system.
S Install Infinity Control according to this instruction.
S Install indoor unit, outdoor unit, and accessories according to
their instructions.
S Wire complete system according to this instruction.
S Setup, commission, and operate system according to this
instruction to assure a smooth and trouble free start-- up.