Frigidaire FEFD67CHSE Installation Instructions Manual

Download Installation instructions manual of Frigidaire FEFD67CHSE Cooktop for Free or View it Online on All-Guides.com.

Brand: Frigidaire

Category: Cooktop

Type: Installation instructions manual for Frigidaire FEFD67CHSE

Pages: 8

Download Frigidaire FEFD67CHSE Installation instructions manual

Frigidaire FEFD67CHSE Installation instructions manual - Page 1
1
Frigidaire FEFD67CHSE Installation instructions manual - Page 2
2
Frigidaire FEFD67CHSE Installation instructions manual - Page 3
3
Frigidaire FEFD67CHSE Installation instructions manual - Page 4
4
Frigidaire FEFD67CHSE Installation instructions manual - Page 5
5
Frigidaire FEFD67CHSE Installation instructions manual - Page 6
6
Frigidaire FEFD67CHSE Installation instructions manual - Page 7
7
Frigidaire FEFD67CHSE Installation instructions manual - Page 8
8
1
30" ELECTRIC RANGE INSTALLATION INSTRUCTIONS
(For 3 Wire, 60 Hz. Systems)
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED TECHNICIAN.
IMPORTANT: SAVE FOR THE LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
1. Clearances and Dimensions
a. Provide adequate clearances between the range and adjacent combustible surfaces.
b. Location—Check location where the range will be installed. Check for proper electrical supply and the stability of
floor.
c. Dimensions that are shown must be used. Given dimensions provide minimum clearance. Contact surface
must be solid and level.
* 30" MINIMUM CLEARANCE BETWEEN THE TOP OF THE COOKING SURFACE AND THE BOTTOM OF AN UNPROTECTED
WOOD OR METAL CABINET; OR 24" MINIMUM WHEN BOTTOM OF WOOD OR METAL CABINET IS PROTECTED BY NOT
LESS THAN 1/4" FLAME RETARDANT MILLBOARD COVERED WITH NOT LESS THAN NO. 28 MSG SHEET STEEL, 0.015"
STAINLESS STEEL, 0.024" ALUMINUM OR 0.020" COPPER. 0" CLEARANCE IS THE MINIMUM FOR THE REAR OF THE
RANGE. FOLLOW ALL DIMENSION REQUIREMENTS PROVIDED ABOVE TO PREVENT PROPERTY DAMAGE, POTENTIAL FIRE
HAZARD, AND INCORRECT COUNTERTOP AND CABINET CUTS.
TO ELIMINATE THE RISK OF BURNS OR FIRE BY REACHING OVER HEATED SURFACE UNITS, CABINET STORAGE
SPACE LOCATED ABOVE THE SURFACE UNITS SHOULD BE AVOIDED. IF CABINET STORAGE IS TO BE PROVIDED,
THE RISK CAN BE REDUCED BY INSTALLING A RANGE HOOD THAT PROJECTS HORIZONTALLY A MINIMUM OF 5"
BEYOND THE BOTTOM OF THE CABINETS.
Recycled paper Printed in Canada P/N 318154300 (9808) Rev. D