Maytag AFU1202BW Service

Download Service of Maytag AFU1202BW Freezer for Free or View it Online on All-Guides.com. This version of Maytag AFU1202BW Manual compatible with such list of devices, as: AFU1202BW, AFU1505BW, AFU2005BW, MQU1556AEW, MQU2056ARW

Maytag AFU1202BW Service - Page 1
1
Maytag AFU1202BW Service - Page 2
2
Maytag AFU1202BW Service - Page 3
3
Maytag AFU1202BW Service - Page 4
4
Maytag AFU1202BW Service - Page 5
5
Maytag AFU1202BW Service - Page 6
6
Maytag AFU1202BW Service - Page 7
7
Maytag AFU1202BW Service - Page 8
8
Maytag AFU1202BW Service - Page 9
9
Maytag AFU1202BW Service - Page 10
10
Maytag AFU1202BW Service - Page 11
11
Maytag AFU1202BW Service - Page 12
12
Maytag AFU1202BW Service - Page 13
13
Maytag AFU1202BW Service - Page 14
14
Maytag AFU1202BW Service - Page 15
15
Maytag AFU1202BW Service - Page 16
16
Maytag AFU1202BW Service - Page 17
17
Maytag AFU1202BW Service - Page 18
18
Maytag AFU1202BW Service - Page 19
19
Maytag AFU1202BW Service - Page 20
20
Maytag AFU1202BW Service - Page 21
21
Maytag AFU1202BW Service - Page 22
22
Maytag AFU1202BW Service - Page 23
23
Maytag AFU1202BW Service - Page 24
24
Maytag AFU1202BW Service - Page 25
25
Maytag AFU1202BW Service - Page 26
26
Maytag AFU1202BW Service - Page 27
27
Maytag AFU1202BW Service - Page 28
28
Maytag AFU1202BW Service - Page 29
29
Maytag AFU1202BW Service - Page 30
30
Maytag AFU1202BW Service - Page 31
31
Maytag AFU1202BW Service - Page 32
32
Maytag AFU1202BW Service - Page 33
33
Maytag AFU1202BW Service - Page 34
34
Maytag AFU1202BW Service - Page 35
35
Maytag AFU1202BW Service - Page 36
36
Maytag AFU1202BW Service - Page 37
37
Maytag AFU1202BW Service - Page 38
38
Maytag AFU1202BW Service - Page 39
39
Maytag AFU1202BW Service - Page 40
40
Maytag AFU1202BW Service - Page 41
41
Maytag AFU1202BW Service - Page 42
42
Maytag AFU1202BW Service - Page 43
43
Maytag AFU1202BW Service - Page 44
44
Maytag AFU1202BW Service - Page 45
45
Maytag AFU1202BW Service - Page 46
46
Maytag AFU1202BW Service - Page 47
47
Maytag AFU1202BW Service - Page 48
48
Maytag AFU1202BW Service - Page 49
49
Maytag AFU1202BW Service - Page 50
50
Maytag AFU1202BW Service - Page 51
51
Component Testing
To avoid risk electrical shock, personal injury, or death,
always disconnect electrical power source to the freezer
before attempting to service, unless test procedures require
power to be connected. When removing any wiring from terminals they must be replaced on the same terminals.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.
WARNING
!
16 16023585 ©2004 Maytag Services
Testing for Leaks
DANGER
!
Free oxygen will explode on contact with oil. Acetylene
will explode spontaneously when put under pressure.
To prevent violent explosions that may result in
serious injury or death to persons in or near the
immediate vicinity, NEVER use oxygen or acetylene
for pressure testing or cleanout of refrigeration
systems.
WARNING
!
To avoid severe personal injury or death from fire,
keep system free from contamination due to presence
of air. Follow instructions exactly.
Electrical System
WARNING
!
To avoid possible electric shock, personal injury or
death disconnect power before servicing. Follow
specific steps listed in this manual for testing or
replacement of a suspected failed component.
All electrical components are grounded to the cabinet.
The green center conductor of three wire lead cord is
also attached to the cabinet to provide a grounding circuit
when the lead cord is plugged into a properly grounded
electrical outlet. After replacing an electrical component,
always verify the ground wire is reconnected.
The electrical outlet from which the appliance is to
receive its power should always be checked to verify it is
properly wired.
Compressor Electrical Tests
Compressor terminals on all models can be reached only
from the rear of the cabinet.
If freezer does not operate, do not assume compressor
has failed until all other possibilities are eliminated.
Is current entering the compressor through the power
cord?
Check for low voltage at the compressor terminals, a
minimum of 100 volts is required for compressor to
start.
If the necessary voltage is available, check for failures
in:
Overload protector
Starting relay
Temperature control
Cabinet wiring harness
Testing Compressor Direct
To test compressor with no other wiring in the circuit is
called “DIRECT TEST”. Safest way to check the
compressor is by using a compressor tester.
Run
Common
Start
Power
cord
Capacitor
connections
Switch
Compressor Tester