Home | About | Contact

Maytag RFS9B Service

Download Service of Maytag 1324704M Microwave Oven for Free or View it Online on All-Guides.com. This version of Maytag 1324704M Manual compatible with such list of devices, as: P1324906M, P1327702M, P1327703M, P1327708M, RCS10MPSED

Maytag 1324704M Service - Page 1
1
Maytag 1324704M Service - Page 2
2
Maytag 1324704M Service - Page 3
3
Maytag 1324704M Service - Page 4
4
Maytag 1324704M Service - Page 5
5
Maytag 1324704M Service - Page 6
6
Maytag 1324704M Service - Page 7
7
Maytag 1324704M Service - Page 8
8
Maytag 1324704M Service - Page 9
9
Maytag 1324704M Service - Page 10
10
Maytag 1324704M Service - Page 11
11
Maytag 1324704M Service - Page 12
12
Maytag 1324704M Service - Page 13
13
Maytag 1324704M Service - Page 14
14
Maytag 1324704M Service - Page 15
15
Maytag 1324704M Service - Page 16
16
Maytag 1324704M Service - Page 17
17
Maytag 1324704M Service - Page 18
18
Maytag 1324704M Service - Page 19
19
Maytag 1324704M Service - Page 20
20
Maytag 1324704M Service - Page 21
21
Maytag 1324704M Service - Page 22
22
Maytag 1324704M Service - Page 23
23
Maytag 1324704M Service - Page 24
24
Maytag 1324704M Service - Page 25
25
Maytag 1324704M Service - Page 26
26
Maytag 1324704M Service - Page 27
27
Maytag 1324704M Service - Page 28
28
Maytag 1324704M Service - Page 29
29
Maytag 1324704M Service - Page 30
30
Maytag 1324704M Service - Page 31
31
Maytag 1324704M Service - Page 32
32
Maytag 1324704M Service - Page 33
33
Maytag 1324704M Service - Page 34
34
Maytag 1324704M Service - Page 35
35
Maytag 1324704M Service - Page 36
36
Maytag 1324704M Service - Page 37
37
Maytag 1324704M Service - Page 38
38
Maytag 1324704M Service - Page 39
39
Maytag 1324704M Service - Page 40
40
Maytag 1324704M Service - Page 41
41
Maytag 1324704M Service - Page 42
42
Component Specifications
!
WARNI NG
To avoid risk of electrical shock, personal injury or death; disconnect power to oven and discharge capacitor
before servicing, unless testing requires power.
16021520 Rev. 0
©2002 Maytag Appliances Company
14
Power Test (Traditional Test Method)
Test equipment required is Amana power test kit R0157397(Fahrenheit), or Menumaster power test kit M95D5
(Celsius).
1. Fill the plastic container to the bottom of the 1000 ml. line with cool tap water.
2. Using the thermometer; stir the water, measure and record the water temperature.
Initial water temperature should be approximately 60°F(20°C).
3. Place container on the center of the oven shelf and heat the water for 62 seconds.
NOTE: Use a watch second hand, not the oven timer.
4. Stir the water, measure and record the temperature of the water after heating time is complete.
5. Subtract the starting water temperature (Step 2), from the ending water temperature (Step 4), to obtain the
temperature rise.
6. See the Temperature Chart provided below.
NOTES: The IEC-705 test method requires precision measurements and equipment. It is not practical to perform
the IEC test in the field. To convert the traditional power test results to the approximate IEC-705 rating,
take the traditional power test results and add 100 watts per magnetron for the unit being tested.
Example: 930 watts output using the traditional power test for model RCS10MP
+ 100
watts (1 magnetrons X 100 watts)
1030 Approximate IEC-705 results
Always perform power test three times for accuracy, changing the water after each test is performed.
Variation or errors in the test procedure will cause a variance in the temperature rise. Additional power
tests should be made if temperature rise appears marginal.
Low line voltage will cause lower temperature rise.
Temperature Chart
ONE MINUTE, THREE SECONDS run time chart for units less than 1550 Watts cooking power
T Cooking T Cooking T Cooking T Cooking
(°F) Power Output (°F) Power Output (°C) Power Output (°C) Power Output
12 464 22 852 7 490 15 1050
13 504 23 891 8 560 16 1120
14 542 24 930 9 630 17 1190
15 580 25 969 10 700 18 1260
16 620 26 1007 11 770
17 659 27 1046 12 840
18 697 28 1085 13 910
19 736 29 1124 14 980
20 775 30 1162
21 814 31 1201