Maytag RFS9B Service

Download Service of Maytag 1324704M Microwave Oven for Free or View it Online on All-Guides.com. This version of Maytag 1324704M Manual compatible with such list of devices, as: P1324702M, P1324703M, P1324706M, RCS10D, RFS10S

Maytag 1324704M Service - Page 1
1
Maytag 1324704M Service - Page 2
2
Maytag 1324704M Service - Page 3
3
Maytag 1324704M Service - Page 4
4
Maytag 1324704M Service - Page 5
5
Maytag 1324704M Service - Page 6
6
Maytag 1324704M Service - Page 7
7
Maytag 1324704M Service - Page 8
8
Maytag 1324704M Service - Page 9
9
Maytag 1324704M Service - Page 10
10
Maytag 1324704M Service - Page 11
11
Maytag 1324704M Service - Page 12
12
Maytag 1324704M Service - Page 13
13
Maytag 1324704M Service - Page 14
14
Maytag 1324704M Service - Page 15
15
Maytag 1324704M Service - Page 16
16
Maytag 1324704M Service - Page 17
17
Maytag 1324704M Service - Page 18
18
Maytag 1324704M Service - Page 19
19
Maytag 1324704M Service - Page 20
20
Maytag 1324704M Service - Page 21
21
Maytag 1324704M Service - Page 22
22
Maytag 1324704M Service - Page 23
23
Maytag 1324704M Service - Page 24
24
Maytag 1324704M Service - Page 25
25
Maytag 1324704M Service - Page 26
26
Maytag 1324704M Service - Page 27
27
Maytag 1324704M Service - Page 28
28
Maytag 1324704M Service - Page 29
29
Maytag 1324704M Service - Page 30
30
Maytag 1324704M Service - Page 31
31
Maytag 1324704M Service - Page 32
32
Maytag 1324704M Service - Page 33
33
Maytag 1324704M Service - Page 34
34
Maytag 1324704M Service - Page 35
35
Maytag 1324704M Service - Page 36
36
Maytag 1324704M Service - Page 37
37
Maytag 1324704M Service - Page 38
38
Maytag 1324704M Service - Page 39
39
Maytag 1324704M Service - Page 40
40
Maytag 1324704M Service - Page 41
41
Maytag 1324704M Service - Page 42
42
©2002 Maytag Appliances Company 16021520 Rev. 0 19
CAUTION!
All repairs as described in this section are to be performed only after the listed caution procedures listed below
have been followed.
Check grounding before checking for trouble.
Be careful of the high voltage circuit.
Discharge high voltage capacitor by shorting across terminals with screwdriver.
When checking the continuity of the switches or the high voltage transformer, disconnect one lead wire from
these parts and then check continuity with the AC plug removed. To do otherwise may result in a false reading
or damage to your meter.
Do not touch any parts of the circuitry on the digital programmer circuit since static electric discharge may
damage this control panel. Always touch yourself to ground while working on this panel to discharge any static
charge in your body.
120 VAC is present in the digital programmer circuit (Terminals of power relay B and primary circuit of low
voltage transformer). When trouble shooting, be cautious of possible electrical shock hazard.
Use of the Schematic and/or Wiring Diagrams will assist the technician on the following component checks.
An Ohmmeter is required for most tests with a Multiplier Scale of X 1OK (k - thousand ohms). Test procedures will
be found elsewhere in this manual.
Troubleshooting Guide
Condition Possible Causes
1. No voltage at outlet.
Line fuse open (external). Check for overload circuit.
2. Voltage available to outlet. No components
operating (including oven light).
Open power cord.
Failed terminal and/or wiring.
Open line fuse. See Condition # 3.
Open cavity thermal fuse.
Open magnetron TCO.
Interlock switch contacts open.
Inoperative p.c. board or electro-mechanical timer.
3. Internal 20, 25 or 30 amp line fuse open.
NOTE:
If line fuse is open, the interlock switch
assembly must be replaced, even if
another component caused the fuse to
open.
Warranty claims involving fuse
replacement will only be paid if switch
assembly is replaced along with the
fuse.
1. Failed terminal and/or wiring in 120 volt circuit of unit.
2. Shorted component in 120 volt circuit of unit.
3. Interlock switch assembly (test).
4. Replace fuse, if fuse blows quickly DO NOT proceed
with step 5: recheck steps 1, 2, and 3.
5. Check amperes and/or wattage compare to
Specifications Sheet (page 9).
6. If fuse blows after running a few seconds, disconnect
power cord, disconnect and tape apart high voltage
transformer primary wires, reconnect power cord.
7. If fuse does not open, disconnect power cord, and
check H.V. components and wiring.
8. If fuse opens, check 120 volt section for loose
connections or grounded wires. The timer, light and
motor by themselves draw less than 1 Ampere. If the
unit opens a fuse while the transformer is
disconnected, there are usually burned areas visible.
NOTE: When taking voltage measurements to the transformer the 120 V supply leads must be connected to the
transformer terminals. The Voltage reading should then be taken with the voltmeter leads also connected to
these terminals.