INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools needed
Phillips screwdriver
Measuring tape
Drill (for wall cabinet installations)
1" (25 mm) drill bit (for wall cabinet installations)
Level
Parts needed
UL listed or CSA approved conduit connector
UL listed wire connectors
Parts supplied
Two #8–14 x 1" screws
Bottom vent (supplied on some models)
Two #8–18 x ³⁄₈" screws - bottom vent (supplied on some
models)
Side trims (supplied on some models)
Two #8–18 x ³⁄₈" screws - side trim (supplied on some
models)
Check local codes. Check existing electrical supply. See
“Electrical Requirements.”
It is recommended that all electrical connections be made by a
licensed, qualified electrical installer.
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance with oven.
Recessed installation area must provide complete enclosure
around the recessed portion of the oven.
Grounded electrical supply is required. See “Electrical
Requirements section.
Electrical supply junction box should be located 3" (7.6 cm)
maximum below the support surface when the oven is
installed in a wall cabinet. A 1" (2.5 cm) minimum diameter
hole should have been drilled in the right rear or left rear
corner of the support surface to pass the appliance cable
through to the junction box.
NOTE: For undercounter installation, it is recommended that
the junction box be located in the adjacent right or left
cabinet. If you are installing the junction box on rear wall
behind oven, the junction box must be recessed and located
in the upper or lower right or left corner of the cabinet;
otherwise, the oven will not fit into the cabinet opening.
Oven support surface must be solid, level and flush with
bottom of cabinet cutout. Floor must be able to support a
single oven weight of 140 lbs (63.5 kg) or a double oven
weight of 245 lbs (111.1 kg).
Undercounter Installation (with cooktop installed above):
Ovens approved for this type of installation have an approval
label located on the top of the oven. Refer to undercounter
installation instructions for cutout dimensions and approved oven
cooktop combinations (separate sheet).
Product Dimensions - Single Oven
Cabinet Dimensions - Single Oven
Single Oven Undercounter (without cooktop installed above)
A. 28³⁄" (72.1 cm) max. recessed width
B. 29" (73.7 cm) max. overall height
C. 29³⁄₄" (75.6 cm) overall width
D. 23" (58.4 cm) max. recessed depth
E. 27¹⁄₂" (69.9 cm) recessed height
A. 30" (76.2 cm) min. cabinet width
B. 1¹⁄" (3.8 cm) min. top of cutout to
underside of countertop
C.5¹⁄₄" (13.3 cm) bottom of cutout to floor
D. 28¹⁄₂" (72.4 cm) cutout width
E. 27³⁄₄" (70.5 cm) min. cutout height
A
B
C
D
E
A
B
C
D
E