OPTIONAL INSTALLATION/CONNECTIONS
Connecting the External Time Signal
If external signal(s) are required, the addition of a relay and signal control board (not supplied)
will be necessary.
Please consult your local electrician.
When a signal is activated, the internal contacts close completing the circuit. These internal
contacts are "dry" and supply no voltage. Voltage applied to these contacts must not exceed 30
volts. An external relay must be used to activate signaling devices.
Recommended Relay and Signal Control Board
Connections
1. Open the unit. Refer to “Open Unit” on page 3.
2. Insert wires into two right terminals for external time signal and tighten both screws. Refer to
Insert Wires into Right Terminals below.
Insert Wires into Right Terminals
Acroprint Relay P/N: 01-0230-000
Acroprint Signal Control Board P/N: 10-0164-000
Be sure to unplug the unit from the wall outlet before connecting wires of the External
Time Signal. Improper connection may cause a malfunction of the unit. Also refer to
“Attaching the Wire Clamp” on page 57 to secure wires with the wire clamp.