Download Installation instructions of ACT Technology ACT1000 Gateway for Free or View it Online on All-Guides.com. This version of ACT Technology ACT1000 Manual compatible with such list of devices, as: ACT1000, ACT1000 - ACCESS CONTROL UNIT - INSTALLERS, ACT2000, ACT2000 - ACCESS CONTROL UNIT - INSTALLERS

ACT Technology ACT1000 Installation instructions - Page 1
1
ACT Technology ACT1000 Installation instructions - Page 2
2
ACT1000/2000 Access Control Unit
(Installers Instructions)
QUICK PROGRAMMING GUIDE
1. Enabling cards
. Enter the operator code.
. Press ü to enter the user set-up menu.
. Press ü to enter the enable menu.
For a single card:
. Use 0 to scroll to the desired card.
. Press ü to enable the card.
For a range of cards:
. Use keys 0-9 to enter the first card. Press ü.
. Use keys 0-9 to enter the last card. Press ü.
. Use X to exit from the menu.
2. Disabling cards
. Enter the operator code.
. Press ü to enter the user set-up menu.
. Press 0, then ü to enter the enable menu.
For a single card:
. Use 0 to scroll to the desired card.
. Press ü to disable the card.
For a range of cards:
. Use keys 0-9 to enter the first card. Press ü.
. Use keys 0-9 to enter the last card. Press ü.
. Use X to exit from the menu.
3. Setting Time and Date
. Enter the operator code
. Use 0 to scroll to “Set Date/Time”
. Press ü to select.
. Use numeric keys 0-9 to Enter the year . Press ü
. Repeat for month, day , hour and minute.
. New time will be displayed. Press ü to Accept.
. Use X to exit from the menu.
Factory default codes:
Operator: 123456
Installer: 999999
4. Setting site code
. Enter the installer code.
. Use 0 to scroll to Card Setup menu.
. Press ü to enter the card setup menu.
. Press ü to enter the site code.
. Use keys 0-9 to enter the eight digit ACT site code.
. Use 0 to exit the menu.
5. Changing Installer code.
. Enter installer code.
. Use 0 to scroll to Change Pin menu.
. Press ü to enter change pin menu.
. Use keys 0-9 to enter new pin.
. Use keys 0-9 to verify pin.
. The controller will display Accepted , the new pin is set.
. Use 0 to exit the menu.
6. Changing relay and output active time.
. Enter the installer code.
. Use 0 to scroll to Door Settings menu.
. Press ü to enter the door settings menu.
. Use 0 to scroll to the door required.
. Press ü to enter the door menu.
. Use 0 to scroll to timers menu.
. Press ü to enter the timers menu.
. Use 0 to scroll to the required timer menu.
. Press ü to enter selected timer menu.
. Use keys 0-9 to enter the time you want the relay or
output to stay active.
. Use 0 to exit the menu.
7. Adding a remote door (ACT2000 Only)
. Enter the installer code.
. Use 0 to scroll to Communications menu.
. Press ü to enter the Communications menu.
. Use 0 to scroll to Remote doors menu.
. Press ü to enter the Remote dooors menu.
. Use 0 to scroll to the required door.
. Press ü to select the door.Use 0 to select Enable/Disable.
. Press ü to Enable or Disable the door as selected.
. Use 0 to exit the menu.
IMPORTANT
As with any access control system, always ensure that there
is an alternate means of escape in the event of the unit fail-
ing to operate due to power loss or in the event of fire.
Unit 8, Tallaght Business Park,
Whitestown, Dublin 24, Ireland.
Tel: 353-1-4622585 Fax: 353-1-4622587
Copyright 2002 Access Control Technology Ltd.
(18-00008-00)
INSTALLATION NOTES
Always remember to factory default the controller before
you start programming.
Always remember to place the supplied Varistor
across the terminals of the door strike coil to protect
the relay contacts.
Don’t forget to change the programming code to
something known only to yourself.
Don’t forget to keep a record of your Site Code for
future use.