Amana ARS9167A Technical Information

Download Technical information of Amana ARS9167A Refrigerator for Free or View it Online on All-Guides.com. This version of Amana ARS9167A Manual compatible with such list of devices, as: ARS9167A, PARS9167AS0, PARS9168AB0, PARS9168AC0, PARS9168AW0

Amana ARS9167A Technical information - Page 1
1
Amana ARS9167A Technical information - Page 2
2
Amana ARS9167A Technical information - Page 3
3
Amana ARS9167A Technical information - Page 4
4
Amana ARS9167A Technical information - Page 5
5
Amana ARS9167A Technical information - Page 6
6
Amana ARS9167A Technical information - Page 7
7
Amana ARS9167A Technical information - Page 8
8
Amana ARS9167A Technical information - Page 9
9
Amana ARS9167A Technical information - Page 10
10
Amana ARS9167A Technical information - Page 11
11
Amana ARS9167A Technical information - Page 12
12
Amana ARS9167A Technical information - Page 13
13
Amana Technical Information Refrigerator
October 2000 RT1300056 Rev.1
1
ARS9167A PARS9167AB0 ARS9168A PARS9168AB0
PARS9167AC0 PARS9168AC0
PARS9167AS0 PARS9168AW0
PARS9167AW0 ARS9169A PARS9169AS0
Due to a possibility of personal injury or property damage, always contact an authorized technician for service
or repair of this refrigerator.
Refer to Service Manual RS1300004 for more information on refrigerator installation, disassembly, icemaker,
safety, testing, and troubleshooting.
Model ARS9167A ARS9168A;
ARS9169A
Capacity 20.6 cu ft 20.6 cu ft
Electrical requirements
separate circuit
115 VAC 60 Hz
15 amps
115 VAC 60 Hz
15 amps
Refrigerant type R134a R134a
Width
without side extrusions
35.75 35.75
Depth
without handle
includes door extrusions
26.2 26.6
Height
including top hinge cap
68.5 68.9
No Load Performance Controls in Normal Position
Kw/24 hr ±0.4
Percent Run Time
±10%
Cycles/24 hr
±25%
Refrigerator
Compartment
Average Food
Temperature ±3°F
Freezer
Compartment
Average Food
Temperature ±3°F
Ambient °F
65° 90° 110° 65° 90° 110° 65° 90° 110° 65° 90° 110° 65° 90° 110°
ARS9167A &
ARS9168A&
ARS9169A
1.2 2.5 4.0 31 63 100 26 19 0 35 35 35 1.5 0 -1
Temperature Relationship Test Chart
T-1 Outlet
±3°F
T-1 Inlet
±3°F
T-3 Suction
Line ±7°F
Average Total
Wattage ±10%
Suction Pressure
±2 PSIG
Head Pressure
±5 PSIG
Ambient °F
65° 90° 65° 90° 65° 90° 65° 90° 65° 90° 65° 90°
ARS9167A &
ARS9168A &
ARS9169A
-20 -17 -17 -15 69 93 153 158 0 1 86 135
!
CAUTION
All safety information must be followed as provided in Service Manual RS1300004.
!
WARNING
To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before
servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires
removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization.