American Standard Yorkvilletm 3125.016 Specification Sheet

Download Specification sheet of American Standard Yorkvilletm 3125.016 Indoor Furnishing for Free or View it Online on All-Guides.com. This version of American Standard Yorkvilletm 3125.016 Manual compatible with such list of devices, as: Yorkvilletm 3125.016, Yorkvilletm 4099.100, Yorkvilletm 4099.700, Yorkvilletm 4099.800, Yorkvilletm 735084-400

American Standard Yorkvilletm 3125.016 Specification sheet - Page 1
1
M42
© 2008 AS America Inc.
Revised 2/08
To Be Specied:
Color: White Bone Linen
Silver Fawn Beige Black
Seat: American Standard #5324.019
Elongated “Rise and Shine” (with easy to clean
lift-off hinge system) solid plastic closed front
seat with cover.
Seat: American Standard #5325.024
Elongated “Rise and Shine” (with easy to clean
lift-off hinge system) solid plastic open front
seat with cover.
Alternate Seat:
Supply with Stop:
* Flushmate III tank system by Flushmate
®
Div. of Sloan Valve Co
YORKVILLE™ 16-1/8" ELONGATED
PRESSURE-ASSISTED TOILET
VITREOUS CHINA
YORKVILLE™ 16-1/8" ELONGATED
PRESSURE-ASSISTED TOILET
2325.101
• Vitreous china
• Low-consumption (6.0 Lpf/1.6 gpf)
Floor-mounted, back-outlet toilet
• Elongated 16-1/8" high bowl
• Pressure-assisted siphon jet ush action
• Side-mounted chrome trip lever
• Close-coupled ushometer tank*
• Speed Connect
®
tank/bowl coupling system
• 4 bolt caps
• Fully glazed 2" ballpass trapway
• 10" x 12" water surface area
• 100% factory ush tested
3125.016 Elongated 16-1/8" high bowl with
four bolt caps and two oor screws
4099.100 Flushometer tank complete with
coupling components
Component parts:
735084-400 Tank cover (specify color)
Nominal Dimensions:
819 x 495 x 803mm
(32-1/4" x 19-1/2" x 31-5/8")
Alternate Congurations:
4099.700 Tank and tank cover only
with tank cover locking device
4099.800 Tank and tank cover only
with right hand trip lever
Fixture only, seat and supply by others
Recommended working pressure range 20 psi - 80ps
Compliance Certications -
Meets or Exceeds the Following Specications:
• ASME A112.19.2 for Vitreous China Fixtures
NOTES:
WASTE OUTLET SEAL RING MUST BE NEOPRENE OR GRAPHITE-
FELT (WAX RING NOT RECOMMENDED).
SUPPLY NOT INCLUDED WITH FIXTURE AND MUST BE ORDERED
SEPARATELY.
*
DIMENSION SHOWN FOR LOCATION OF SUPPLY IS SUGGESTED.
FOR ADDITIONAL INFORMATION REFER TO INSTALLATION
INSTRUCTIONS SUPPLIED.
IMPORTANT: Dimensions of xtures are nominal and may vary within
the range of tolerances established by ANSI Standard A112.19.2. These
measurements are subject to change or cancellation. No responsibility is
assumed for use of superseded or voided pages.
803mm
(31-5/8)
235mm
(9-1/4)
410mm
(16-1/8)
381mm
(15)
470mm
(18-1/2)
648mm
(25-1/2)
819mm
(32-1/4)
C/L OF SEAT
POST HOLES
140 mm (5-1/2)
CENTER
FINISHED WALL
FINISHED
FLOOR
152 mm
(6)
64mm (2-1/2)
324mm
(12-3/4)
C/L OF 1/2" DIA HOLES
152mm (6) CENTERS
76mm
(3)
76mm
(3)
102 mm
(4)
C/L OF
WASTE
OUTLET
13 x 19mm
(1/2 x 3/4)
SLOTS
FLEX
SUPPLY
AS REQ.
C/L
*
222mm
(8-3/4)
19mm ± 6mm
(3/4 ± 1/4)
495mm
(19-1/2)
279mm
(11)
Replaces 2325.100
MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES AND
ANSI A117.1 REQUIREMENTS FOR ACCESSIBLE AND USABLE
BUILDING FACILITIES-CHECK LOCAL CODES.
BARRIER FREE