MODEL: BZCAPT20
2 FARAD POWERFUL TRIANGLE CAPACITOR.
Capacitance------------------------------------ 2,000,000 micro farad (2 farad)
Working Voltage------------------------------ 21 DC
Surge Voltage---------------------------------- 24 DC
E.S.R. (Equivalent Series Resistance)------ 0.0015 ohm @120hz/ 25°C
Capacitance Tolerance------------------------ ± 10%
    
         
    
You must first attach the mounting tabs to the Stiffening Capacitor before
mounting it. Use the supplied hardware shown in the picture to the right.
Notice the small mounting screw hole in the capacitor chassis.

 

Detail function:
a) 4-digit hi-end red light display DC voltage meter that can measure 0.01
DCV range. And PCB working status Flash blue LEDS (4pcs).
b) Electronic Polarity Protection Circuit. If the capacitor is connected
incorrectly by reversing the positive and negative wires during the
installation process, the PCB will issue a 45 seconds noise to warn you.
c) Over-voltage Protection Circuit. When the install system voltage over
17.5 DCV or LESS 10 DCV limit, the buzz on the PCB will issue an
audible noise warning.
d) Lowest E. S. R. 24 DCV foil with maximum moment discharge power
in lowest E. S. R..
2
   
      
       
       
   
The capacitor must be charged before connecting the Power and Ground
cables to the capacitor. Failure to charge the capacitor will result in a
large spark generated from the rapid inflow of current.
B ATTER Y
+
)(
--
)(
C H AR G IN G
BU LB
To Charge the capacitor:
1. Make Capacitor positive terminal connections with amplifier and
tighten the bolt. Do not over-tighten the bolts!
Caution: Stripped terminals are not covered under the capacitor’s
warranty.